湿帘系统循环运行降温初探

Research the Cycle Running of the Wet Curtain Cooling System
下载PDF
导出
摘要 为了有效减小夏季玻璃温室的降温成本,针对减小湿帘风机循环运行降温的成本进行了探索性研究试验。试验结果表明:在夏季高温上午时段,利用Eldar控制系统控制湿帘风机的运行时间,当把温室内的温度设定在32~35℃时,在153min的时间段内,湿帘系统中水泵运行了43min,风机运行了68min;温室内温度与湿度成反比关系,温度越低,湿度越高;Eldar控制系统设定的温度差越大,湿帘风机开启的次数越少,运行的时间也越短。 In this paper, it has the experiment of the cycle running of the wet curtain cooling system that reduces a higher-cost in summer. The results show that in the morning in summer, the Eldar pilot control system is used to set the temperature in 32 - 35℃, pumps of the wet curtain system runs 43 min, fan runs 68min at the 153min time period; the relationship of temperature and humidity in the greenhouse is inversely proportional, the lower the temperature, the higher the humidity; the pan-and-fan opens less time and runs more short when the Eldar control system is used to set the greater difference of the temperature.
出处 《中国农村水利水电》 北大核心 2009年第12期103-105,共3页 China Rural Water and Hydropower
关键词 温室降温 湿帘循环 节能 温湿度关系 greenhouse cooling wet curtain cycle energy the relationship of temperature and humidity