摘要 为了考察DSC3200型表面曝气机的性能,将该表面曝气机与Landy-F表面曝气机的充氧性能、推流能力和实际污水处理厂的应用情况进行了对比研究。结果发现DSC3200型表面曝气机叶轮和Landy-F曝气叶轮的充氧能力分别为2.5~2.7和2.1~2.3kg[O2]/kW.h。通过实际氧化沟工艺污水处理厂现场流速测试结果发现,在额定功率下DSC3200的推流能力小于Landy-F的推流能力。二者在氧化沟内的的平均流速分别为0.23和0.26m/s。通过污水处理厂的硝化效果发现DSC3200型倒伞表面曝气机的充氧能力大于Landy-F型倒伞表面曝气机。 In order to investigate the performance of surface aerator DSC3200, a comparative study on oxygenation capability, plug-flow capacity and actual application of the said aerator and surface aerator Landy-F in sewage treatment plant was carried out. The results showed that, the oxygenation capability of the impellers of surface aerator DSC3200 and Landy-F were 2.5 - 2.7 and 2.1 - 2.3 kg[Oi]/kW·h respectively. Through the flow velocity test of the actual oxidation ditch process in the sewage treatment plant, it could be found that, the surface aerator Landy-F had a higher ping-flow capacity compared with the surface aerator DSC3200, the average flow velocity of the said two aerat6rs in oxidation ditch process were 0.23 and 0.26 m/s respectively, the nitrification effect indicated that, the oxygenation capability of the surface aerator DSC3200 was higher than that of the surface aerator Landy-F.
出处 《工业用水与废水》 CAS 2009年第6期74-77,共4页 Industrial Water & Wastewater
基金 "十一五"国家科技支撑计划重点项目(2006BAC19B02)
关键词 表面曝气机 氧化沟 充氧性能 推流能力 surface aerator oxidation ditch oxygenation capability plug-flow capacity
  • 相关文献

参考文献11

二级参考文献27

  • 1赵书华,李长坤,李保臣,陈顺杰.改良型Carrousel 2000氧化沟工艺的优化控制[J].江苏环境科技,2004,17(3):15-16. 被引量:22
  • 2米克尔G曼特(美) 布鲁斯A贝尔.污水处理的氧化沟技术[M].北京:中国建筑工业出版社,1988.1-135.
  • 3.GBJ 14-87.室外排水设计规范[S].,..
  • 4GBJ 14—87.室外排水设计规范[S].[S].,..
  • 5米克尔G曼特(美) 布鲁斯A贝尔.污水处理的氧化沟技术[M].北京:中国建筑工业出版社,1988.1-135.
  • 6张忠祥,钱易.废水生物处理技术[M].北京:清华大学出版社.2004:403—434.
  • 7HOLMAN J B,WAREHAM D G.COD,ammonia and dissolved oxygen time profiles in the simultaneous nitrification/denitrifacation process[J].Biochemical Engineering Journal,2005(22):125-33.
  • 8HYNGSEOK Y,KYU-HONG A,HYUNG-JIB L,et al.Nitrogen removal from synthetic wastewater by simultaneous nitrification and denitrification (SND) via nitrite in an intermittently-aerated reactor[J].Wat.Res,1999:33(1):145-54.
  • 9RIKKE L M,RAYMOND J Z,VALERIO G,et al.Challenges for simultaneous nitrification,denitrification,and phosphorus removal in microbial aggregates:mass transfer limitation and nitrous oxide production[J].FEMS Microbiology Ecology,2005(52):329-38.
  • 10BERTANZA G.Simultaneous nitrification-denitrifacation process in extended aeration plants:pilot and real scale experiences[J].Wat.sci.tech,1997,35(6):53-61.