数字化变电站中电子式互感器接口研究

Research on Interfaces of Electronic Transformers in Digital Substation
下载PDF
导出
摘要 根据相关国际标准IEC60044-7/8和IEC61850-9,为适应数字化变电站的要求,电子式互感器与二次保护控制设备间采用合并单元实现数字接口。简要介绍了合并单元在相关国际标准IEC60044-7/8、IEC61850-9-1和IEC61850-9-2中的区别,同时对合并单元的主要功能和实现方法进行了研究和比较。 According to intematinal standards of IEC60044-7/8 and IEC61850-9, the merging unit between the electrinic transformer and the protected control device is adopted to achieve digital interfaces in order to suit the requirements of digital substations. The paper presents differences of the merging unit in ternational standards of IEC60044-7/8, IEC61850-9-1 and IEC61850-9-2. Meanwhile,the main function and achieved method for the merging unit are studied and comparied.
作者 潘珍 王佳琳
出处 《电气开关》 2009年第6期4-7,共4页 Electric Switchgear
关键词 数字化变电站 合并单元 digital substation merging unit
  • 相关文献

参考文献7

二级参考文献20

  • 1殷志良,刘万顺,秦应力,杨奇逊.一种基于FPGA技术的电子式互感器接口实现新方法[J].电力系统自动化,2004,28(14):93-96. 被引量:53
  • 2贺志容,叶妙元,肖霞,赵玉富.基于CPLD的AOTV单光纤传输方案[J].高电压技术,2004,30(10):32-33. 被引量:5
  • 3International Electrotechnical Commission. IEC 60044 - 8 Instrument transformers part 8:electronic current transducers[S]. [S.l.]:IEC, 2002.
  • 4STALLINGS W.数据与计算机通信[M].王海,张娟,蒋慧,等,译.北京:电子工业出版社,2001.
  • 5RAMABADRAN T V,GAITONDE S S. A tutorial on CRC computations[J]. IEEE Micro, 1988,8(4) :62-75.
  • 6IEC60044-8. Instrument Transformers-part8: Electronic Current Transducers IEC/TC38[S]. 2000: 1-94.
  • 7R Gross, H J Hermann, U Katschinski. Substation Control and Protection Systems for Novel Sensors [J]. CIGRE Session,Paris, 2000, 12(23): 34-03.
  • 8IEC60044 -8.Instrument Transformers-part 8:Electrical Current Transducers[S].2002.
  • 9IEC61850-9-1.Communication Networks and Systems in Substations-part 9 -1:Specific Communication Service Mapping-sampled Value Over Serial Unidirectional Multidrop Point to Point Link[S].2003.
  • 10Bob Zeidman.Designing with FPGAs & CPLDs[M].Lawrence(KS):CMP Books,2002.