期刊文献+

基于光纤光栅传感器的人体心率测量技术研究 被引量:8

Research on human heartrate measurement based on fiber Bragg grating sensor technology
下载PDF
导出
摘要 光纤光栅以其抗电磁干扰、体积小、寿命长、柔韧性好等特点,是构成智能服装的最具潜力的材料。文中根据人体心率信号的特点,设计了由金属材质构成的振动腔,采用ANSYS分析了腔的振动过程,确定了光纤光栅的封装方式,并在实验室中实现了心率信号的采集,完成了数据分析与信号提取的算法。实验结果表明:该传感器可完成人体心率信号的实时在线的采集与分析,测量误差小于1次/min。 FBG is the most potential material for intelligent clothing because it has the characteristics such as anti-electromagnetic interference, small size,long life and good flexibility. According to the characteristics of the human heartrate signal, the metal vibration cavity was designed. ANSYS was used to analysis the vibration of the cavity and determined the the FBG package method. Then in the laboratory the system achieved heart rate signal acquisition,completed the data analysis and signal extraction algorithms. The experimental results show that:the sensor completed signal acquisition and analysis in real-time online and the measurement error is less than 1 times/min.
出处 《激光与红外》 CAS CSCD 北大核心 2009年第12期1317-1320,共4页 Laser & Infrared
基金 国家自然科学基金项目(No.60844002)资助
关键词 智能服装 光纤光栅 心率测量 小波变换 intelligent clothing FBG heart rate measurement wavelet transform
  • 相关文献

参考文献9

二级参考文献53

  • 1黄山,赵华凤,俞涛,周开军,刘海涛.光纤光栅温度补偿桥式结构[J].半导体光电,2003,24(6):439-440. 被引量:10
  • 2王跃,张伟刚,杨翔鹏,刘艳格,刘志国,赵启大,董孝义.光纤布拉格光栅的半金属管封装及挠度实验研究[J].传感技术学报,2002,15(3):203-207. 被引量:12
  • 3袁俊泉,马晓岩,张长耀.基于实际数据的海杂波特性分析[J].空军雷达学院学报,2001,15(1):4-8. 被引量:3
  • 4颜良,陈儒军,刘石,陈一平.基于UAF42通用滤波芯片的50Hz陷波器设计[J].仪器仪表学报,2006,27(8):924-927. 被引量:23
  • 5俞梦孙 杨军 等.用微动敏感床垫监测睡眠的研究[J].中华航空航天医学杂志,1999,10(1):40-45.
  • 6Trefny Z, Trojan S, Toman V, et al. New trends in ballistocardiography[J ]. Measure Science Review, 2003,3 (2) :45 - 48.
  • 7Kim J M, Hong J H, Cha E J. Development of ECG and BCG measuring system on moving wheelchair using CDMA network[C]//6th International Special Topic Conference on ITAB. Tokyo: IEEE, 2007:179 181.
  • 8Jansen B, Larson H, Shankar K. Monitor of the ballistocardiogram with the static charge sensitive bed [J ]. IEEE Transactions on Biomedical Engineering, 1991,38 (8) : 748 -751.
  • 9Junnila S, Akhbardeh A, Barna L C, et al. A wireless hallistocardiographic chair [ C ] //Proceedings of the 28th Annual International Conference of the IEEE EMBS. New York: IEEE, 2006:5932- 5936.
  • 10Texas Instruments. Universal active filter [EB/OL]. (2007 -12- 24)[2008-2 15]. http://focus. ti. com. cn/cn/ lit/ds/symlink/ua f42. pdf.