期刊文献+

火焰原子吸收光谱法测定磷矿中氧化镁含量的测量不确定度评定 被引量:3

Evaluation of the Uncertainty of Determination of Magnesiun Oxide Content in Phosphate Rock by Flame Atomic Absorption Spectrometric Method
下载PDF
导出
摘要 在文章中,对火焰原子吸收光谱法测定磷矿石中氧化镁含量的不确定度进行了评定,分析了测量不确定度的来源,包括标准曲线拟合引入的不确定度、标准溶液的不确定度、试样称量和预处理的不确定度等。通过评定,标准曲线拟合引入的不确定度最大。 The uncertainty of determination of magnesium oxide content in phosphate rock by flame atomic absorption spectrometric method was evaluated. The main sources of uncertainty were analyzed, which included synthesizing of standard curve, the uncertainty of the standard solution, the weight and foreordain disposal of the sample so on. By evaluation, the uncertainty of synthesizing the standard curve plays the largest role in all.
作者 黄娟 刘丽英
出处 《广东化工》 CAS 2009年第12期156-158,160,共4页 Guangdong Chemical Industry
关键词 不确定度 磷矿 氧化镁 火焰原子吸收光谱法 评定 uncertainty phosphate magnesium oxide flame atomic absorption spectrometric method evaluate
  • 相关文献

参考文献3

  • 1中国合格评定委员会.CNAS-CL01:2006,检测和校准实验室能力认可准则[M].
  • 2国家技术监督局.JJF1059-1999测量不确定度评定与表示[M].北京:中国计量出版社,1999.
  • 3国家技术监督局.磷矿石和磷精矿中氧化镁含量的测定-火焰原子吸收光谱法[S].中国标准出版社,GB/T18715.1995.