基于肌电图的呼吸机人机同步新方法的研究 被引量:1

Research on a New Method to Trigger Ventilator Based on Electromyogram
原文传递
导出
摘要 基于膈肌肌电图(EMG)实现呼吸机人机同步的新方法,旨在解决困扰传统呼吸机的"人机对抗"问题。研究膈肌电信号的采集、处理方法,以及呼吸特征参数的提取方法,发现对膈肌肌电信号进行适当处理后生成的包络线可以取代传统的呼吸流量曲线,从中检测出呼吸过程的吸气点、呼气点和呼吸周期等特征参数。通过自行定义的"肌电功率"参数的计算分析,发现在重复呼吸试验下呼吸容积曲线和膈肌肌电功率曲线具有较高的相关性,初步论证了呼吸机人机同步新方法的可行性。 In order to improve synchrony between a ventilator and its patient, a new method for triggering a ventilator based on diaphragmatic electromyogram (EMG) is introduced. The methods to extract and process diaphragmatic EMG signals are studied. It has been shown that the characteristic parameters of a respiration activity, such as inspiratory beginning point, expiratory beginning point and respiration period, can be detected from diaphragmatic EMG envelop instead of traditional flux curve. A new parameter, designated as diaphragmatic "Intensity of EMG" for short "IEMG",is defined. Repeat respiration tests have disclosed that there is relatively high correlation between the diaphragmatic IEMG curve and its corresponding eubage curve. These results primarily demonstrate that the new synchronization method may be feasible.
出处 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2009年第6期1222-1226,1254,共6页 Journal of Biomedical Engineering
基金 广东省自然科学基金资助项目(06104744) 广东省科技计划资助项目(2004B10401017)
关键词 呼吸机 人机同步 膈肌肌电图 呼吸流量 肌电强度 Respirator Respiration synchronization Intensity of electromyogram Diaphragmatic electromyogram Respiration flux
  • 相关文献

参考文献10

  • 1CHAO D C, SCHEINHORN D J, STEARN-HASSENPFLUG M. Patient-ventilator trigger asynchrony in prolonged mechanical ventilation[J]. Chest, 1997,112(6):1592- 1599.
  • 2LUO Y M, N HART, N MUSTFA, et al. The effect of diaphragm fatigue on neural respiratory drive [J]. Physiol, 2001,90(4) : 1691-1699.
  • 3PARTHASARATHY S, JUBRAN A, TOBIN M J. Cycling of inspiratory and expiratory muscle groups with the ventilator in airflow limitation[J]. Am J Respir Crit Care Med, 1998,158(5 Pt 1):1471-1478.
  • 4PARTHASARATHY S, JUBRAN A, TOBIN M J. Assessment of neural inspiratory time in ventilator-supported patients[J]. Am J Respir Crit Care Med, 2000, 162(2 Pt 1): 546-552.
  • 5MAARSINGN E J W, EYKERN L A, SPRIKKELMAN A B. Ventilatory muscle activity measured with a noninvasive EMG technique : technical aspects and reproducibility [J]. Journal of Applied Physiology, 2000,88:1955-1961.
  • 6郑则广,陈荣昌,王思华,陈思蓓,罗群,李寅环,黎毅敏,郑劲平,钟南山.食管膈肌肌电图在呼吸机触发中的应用[J].中国实用内科杂志,2004,24(11):659-660. 被引量:12
  • 7CHEN Y, DUAN H. A QRS complex detection algorithm based on mathematical morphology and envelope[C]. Shanghai, China:The 27th IEEE Annual Conference on Engineering in Medicine and Biology, 2005:4654-4657.
  • 8SUN P, WU Q H, WEINDLING A M, et al. An improved morphological approach to background normalization of ECG signals[J]. IEEE Transactions on Biomedical Engineering, 2003,50(1):117-121.
  • 9MARQUE C, BISCH C, DANTAS R, et al. Adaptive filtering for ECG rejection from surface EMG recordings[J]. Journal of Electromyography and Kinesiology, 2005,15 (3) : 310- 315.
  • 10LU Y S,XIAN Y,CHEN J F, et al. A comparative study to extract the diaphragmatic electromyogram signal[C]. Sanya, Hainan,China: The First International Conference on Biomedical Engineering and Informatics, 2008 :315-319.

二级参考文献4

  • 1Sassoon CS,Foster GT.Patient-ventilator asynchrony.Curr Opin Crit Care,2001,7(1):28-33
  • 2Luo YM,Polkey MI,Johnson LC,et al.Diaphragm EMG measured by cervical magnetic and electrical phrenic nerve stimulation.J Appl Physiol,1998,85(6):2089-99
  • 3Leung PA,Jubran,Tobin MJ.Comparison of assisted ventilator modes on triggering,patient effort,and dyspnea.Am J Respir Crit Care Med,1997,155(10):1940-1948
  • 4Sairam P,Amal J,Artin J,et al.Cycling of inspiratory and expiratory muscle groups with the ventilator in airflow limitation.Am J Respir Crit Care Med,1998,158(5):1471-1478

共引文献11

同被引文献9

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部