摘要
在电站中,内置喷雾式除氧器和淋水盘一体化除氧器都有着广泛的应用,虽然两者在结构上存在较大的差异,各有优缺点,但在CPR1000核电机组的正常运行工况下,两者均可满足要求。在汽轮机旁路运行工况下,小喷嘴一体化除氧器内部压力会迅速上升,可通过系统的优化或设备结构的适当改进,解决此工况下的超压问题。
Spray integrated deaerator and tray deaerator are widely used in power plants. All of them can be used in the CPR 1000 unit on normal operation, although there are many differences in the structure and they have merits and demerits respectively. The pressure of tray deaerator will increase rapidly in the turbine bypass operating condition, and the overpressure problem can be resolved by system optimization or equipment improvement.