摘要
机组在整套启动时,首次启动发现汽轮机汽轮机轴振较大,5500r/min时,2号轴承大轴振动2Y约140—150μm,然后,进行振动分析和处理,机组轴系振动全部达到优良标准。
During the commissionning of the whole unit, when it firstly rises up to 5 500 r/min, the max. shaft vibration takes place, that is, No. 2 bearing vibrates 140 - 150μm in y direction. And then, the shaft vibration of the unit meets the requirements of the criterion by analyzing and disposing the vibration.
出处
《四川电力技术》
2009年第6期49-49,58,共2页
Sichuan Electric Power Technology
关键词
B25
MW汽轮机
轴系振动
分析
处理
B25 MW steam turbine
shaft vibration
analysis
treatment