期刊文献+

510L汽车大梁钢冷弯、拉伸异常断口原因分析 被引量:1

The Reason Analysis for Abnormal Fracture in Cold Bending and Stretching of 510L Automobile Crossbeam Steel
下载PDF
导出
摘要 510L汽车大梁钢热轧钢板在进行冷弯、拉伸试验时,发现断口异常,呈台阶状,伸长率远低于标准要求。通过观察断口宏观形貌和金相显微组织,证实连铸坯表面纵裂纹引起的高温氧化和严重的带状组织是引起断口异常,并诱发伸长率不合格的根本原因。 Abnormal fracture of step appearance has been found during cold bending and stretching tests were conducted on hot rolled steel plate of 510L automobile crossbeam steel, and the elongation ratio was much lower than the standard value. By inspecting macro shape and metallographie microstructure of fracture, it is verified that high temperature oxidation and serious banded structure caused by the longitudinal crack on continuous casting blank are essential factors to cause abnormal fracture and unqualified elongation ratio.
作者 岳好明
出处 《中国重型装备》 2009年第4期23-25,共3页 CHINA HEAVY EQUIPMENT
关键词 汽车大梁钢 异常断口 伸长率 高温氧化 带状组织 automobile crossbeam steel abnormal fracture elongation ratio high-temperature-oxidation banded structure
  • 相关文献

参考文献1

二级参考文献3

  • 1[1]Sakir Bor A. Effect of Pearlite Banding on Mechanical Properties of Hot-rolled Steel Plates. ISIJ. Int. , 1991, 31(12):1445~1446.
  • 2[2]WENG Yuqing.Development of Ultrafine Grained Steel in China.NG Steel'2001.Beijing:2001.1~7.(翁宇庆.Development of Ultrafine Grained Steel in China.新一代钢铁材料研讨会.北京:2001.1~7.)
  • 3[3]Palmiere E J. The Influence of Niobium Super-saturation in Austenite on the Static Recrystallization Behavior of Low Carbon Microalloyed Steels. Metall. Trans. , 1996, 27A(4):951.

共引文献28