期刊文献+

心脏反搏辅助装置研究进展 被引量:4

Advances in Counterpulsation Device
下载PDF
导出
摘要 目前,全球心力衰竭患者的发病率及病死率逐年增加。机械辅助循环已成为治疗心力衰竭的主要方法之一,其中反搏法辅助心脏的实验研究及临床应用已成为热点,具有代表性的主动脉球囊反搏已成为目前临床最常用的治疗心功能不全的短期机械辅助装置。近年来,主动脉旁反搏装置及其它各种新型反搏装置的研发也取得了快速发展,现对反搏原理、发展历史及各种不同反搏装置的进展进行综述。 Today,the morbidity and mortality of heart failure are increasing year by year in the world. Mechanical circulatory assist devices has been one of the most effective ways to treat heart failure. The experimental study and clinical application of counterpulsation technique are now becoming more and more popular.Intra-aortic balloon pump is representative,and has become the most frequently used short-term mechanical assist device to treat heart failure. Recently,para-aortic counterpulsation device and other new counterpulsation devices have been developing very rapidly. The principle of counterpulsation and its historical background,as well as the development of various counterpulsation devices are reviewed in this paper.
出处 《中国胸心血管外科临床杂志》 CAS 2009年第6期480-484,共5页 Chinese Journal of Clinical Thoracic and Cardiovascular Surgery
关键词 心力衰竭 反搏法 机械辅助循环装置 Heart failure Counterpulsation technique Mechanical circulatory assist devices
  • 相关文献

参考文献36

  • 1Dec GW. Management of heart failure: crossing boundary over to the surgical country. Srug Clin North Am, 2004, 84(1) :1-25.
  • 2Kantrowitz A. Experimental augmentation of coronary flow by retardation of the arterial pressure pulse. Surgery ,1953, 34(4) 678-687.
  • 3Moulopoulos SD, Topaz S, Kolff WJ. Diastolic balloon pumping (with carbon dioxide)in the aorta-a mechanical assistance to the failing circulation. Am Heart J, 1962,63 : 669-675.
  • 4Kantrowitz A, Krakauer J, Zorzi G, et al. Current status of intraaortic balloon pump and initial clinical experience with aortic patch mechanical auxiliary ventricle. Transplant Proc, 1971,3 (2):1459- 1471.
  • 5Ryan EW, Foster E. Lmages in cardiovascular medicine. Augmentation of coronary blood flow with intra-aortic balloon pump counter-pulsation. Circulation, 2000,102 (3):364-365.
  • 6Bhayana JN, Scott SM, Sethi GK, et al. Effcots of intraaortic balloon pumping on organ perfusions in cardiogenic shock. J Surg Res, 1979,26(2):108-113.
  • 7Sugita Y, Emoto H, Morha K, et al. The effect of intraaortic balloon pumping (IABP) on pulmonary circulation. Am Soc Artif Intern Organs Trans, 1985,31:389-394.
  • 8Hilberman M, Derby GC, Spencer RJ, etal. Effect of the intraaortic balloon pump upon postoperative renal function in man. Crit Care Med ,1981, 9(2): 85-89.
  • 9Papaioannou TG, Stefanadis C. Basic principles of the intraaortic balloon pump and mechanisms affecting its performance . ASAIO J, 2005,51(3) :296-300.
  • 10Sherwood JT, Schomisch SJ, Thompson DR, et al. Aortomyoplasty : hemodynamics and comparison to the intraaortie balloon pump. J Surg Res, 2003, 110(2) :315-321.

同被引文献28

  • 1彭彩虹,康磊.主动脉内球囊反搏在重症冠心病患者围手术期护理中的应用[J].上海交通大学学报(医学版),2011,31(6):720-722. 被引量:12
  • 2赵龙,刘晓程,张杰民,杨力.外置主动脉旁反搏装置的慢性动物实验研究[J].生物医学工程研究,2013,32(1):26-30. 被引量:2
  • 3伍贵富,杜志民,方典秋,徐明国,马虹,郑振声,王奎健.体外反搏的生物力学效应与血管内皮功能[J].中山大学学报(医学科学版),2005,26(2):121-124. 被引量:35
  • 4侯晓彤,蔺嫦燕,吴广辉,李冰一,王璟.XZ-IIA型轴流血泵血液相容性的研究[J].透析与人工器官,2005,16(3):23-28. 被引量:4
  • 5Koenig S C, Litwak K N, Giridharan G A, et al. Acute hemodynamic efficacy of a 32-ml subcutaneous counterpulsation device in a calf model of diminished cardiac function [J]. ASAIO J, 2008, 54(6) :578-584.
  • 6Dec G W. Management of heart failure:crossing boundary over to the surgical country [J]. Srug Clin N, 2004,84(1):1-25.
  • 7Sayer G, Naka Y, Jorde U P. Ventricular assist device therapy[J]. Cardiovasc Ther, 2009,27 (2) : 140-150.
  • 8Zelano J A, Ko W, Lazzaro R, et al. Evaluation of an extraaortic counterpulsation device in severe cardiac failure [J]. Ann Thorac Surg, 1992,53( 1 ) : 30-37.
  • 9Stamatelopoulos S F, Nanas J N, Saridakis N S, et al. Treating severe cardiogenic shock by large counterpulsation volumes[J]. Ann Thorac Surg, 1996,62(4):1110-1117.
  • 10Charitos C E, Nanas J N, Kontoyiannis D A, et al. The efficacy of the high volume counterpulsation technique at very low levels of aortic pressure [J]. J Cardiovasc Surg(Torino), 1998,39 ( 5 ) : 625-632.

引证文献4

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部