提出了2种能考虑火灾时钢筋混凝土板薄膜效应的极限承载力计算方法。在塑性铰线理论的基础上,利用板块平衡法和虚功法对火灾时钢筋混凝土板的承载力进行了计算,并将计算结果与试验结果进行了对比。结果表明:承载力计算结果与试验结果吻合良好;提出的方法适用于各向同性和各向异性配筋的方形板和矩形板;采用该方法可以解释相同条件下方形板和矩形板产生的破坏挠度不同的原因。
Two methods which could consider tensile membrane action were offered to calculate the limit bearing capacity of reinforced concrete slabs in fire conditions. Based on yield hinge line theory, the bearing capacity of reinforced concrete slabs in fire conditions was calculated by using segment equilibrium method and energy-based method. The comparison of calculated results and test results was carried out. The results show that the methods can be applied to sqaure slabs and rectangular slabs with orthotropic and isotropic renforcement. The models can interpret why the difference between sqaure slabs and rectangular slabs exists under the same condition.
出处
《建筑科学与工程学报》
CAS
2009年第4期14-23,共10页
Journal of Architecture and Civil Engineering
基金
"十一五"国家科技支撑计划项目(2006BAJ13B03)
国家自然科学基金项目(50878069)
关键词
钢筋混凝土板
板块平衡法
虚功法
极限承载力
塑性铰线
高温
火灾
reinforced concrete slab
segment equilibrium method
energy-based method
limit bearing capacity
yield hinge line
elevated temperature
fire