期刊文献+

基于T1的磁共振成像实时无创测温的研究 被引量:1

Real-Time Non-Invasive Temperature Measurement With MRI Based on T_1
下载PDF
导出
摘要 利用磁共振成像(MRI)开展无创测温方法研究,探讨了基于T1加权成像无创测温的理论和方法;在实验数据的基础上建立了相应的理论温度模型,并对样品所得理论温度与数字温度计实测温度进行了对比.结果表明,基于T1加权成像无创测温方法能够较准确测量生物组织的温度,所需时间在5s以内,可以实现实时无创温度监测. The non-invasive temperature measurement with MRI(magnetic resonance imaging) is investigated,and the theory and methods based on the non-invasive temperature monitoring on T1 with MRI are discussed.A corresponding theoretical temperature model by means of the experimental data is given,and a comparison of the theoretical temperature with the measured temperature by using a thermometer is made.It is shown that the non-invasive temperature monitoring on T1 with MRI can obtain the temperamre of the biological tissue with better accuracy and within 5 seconds, which makes it possible for the tissue temperature changes to be monitored in real-time and non-invasively.
出处 《电子学报》 EI CAS CSCD 北大核心 2009年第12期2770-2773,共4页 Acta Electronica Sinica
基金 国家高技术研究计划(No.2006AA04Z216)
关键词 热疗 无创测温 磁共振成像(MRI) 弛豫时间T1 thermotherapy non-invasive temperature monitoring magnetic resonance imaging(MRI) spin-lattice relaxation time T1
  • 相关文献

参考文献9

  • 1Young IR, Hand JW, Oatridge A, et al. Modeling and observation of temperature changes in vivo using MRI[ J]. Magn Reson Med,2002,32(3) :358.
  • 2Bloembergen N, Purcell EM, Pound RV. Relaxation effects in nuclear magnetic resonance absorption[ J]. Phys Rev, 1948,73 (7) :679 - 712.
  • 3Wong SH, Watkins RD, Kupnik M, et al. Feasibility of MR- ternperature mapping of ultrasonic heating from a CMUT[ J]. IEEE Trans,2008,55(4) :811 - 818.
  • 4RistoA K, Rishma V, Charmaine C, et al. Assessment of human brain temperature by 1H MRS during visual stimulation and hypercapnia[ J]. NMR in Biomedicine, 2008,21 (4) : 388 - 395.
  • 5Kent RT, Robert Tycko. Measurement of sample temperatures under magic-angle spinning from the chemical shift and spin- lattice relaxation rate of 79Br in KBr powder[ J]. Journal of Magnetic Resonance, 2009,196( 1 ) : 84 - 87.
  • 6Ir GJ Strijkers, W van Marken Lichtenbelt, L Prinzen, et al. Temperature mapping with gradient echo MR imaging [ J ]. Magnetic Resonance Medicine, 2003,2: 34 - 41.
  • 7Jacco Ade Zwart, Frederic C Vimeux, et al. Fast lipid- suppressed MR temperature mapping with echo-shifted gradient-echo imaging and spectral-spatial excitation[ J ]. Magnetic Resonance in Medicine, 1999(1), 42: 53 - 59.
  • 8Shapiro EM,Borthakur A, Shapiro MJ,Reddy R, Leigh JS.Fast MRI of RF heating via phase difference mapping[ J ]. Magnetic Resonance in Medicine,2002,47(3) :492 - 498.
  • 9Hindman JC. Proton resonance shift of water in the gas and liquid states[J]. Chem Phys. 1966 44:4583 - 4589.