摘要
由于钢筋混凝土电解槽设计抗渗等级高,对表面平整和垂直度要求较高,存在制作难度大,质量难以控制的问题,文章结合清水混凝土应用技术规程要求阐述了如何对混凝土电解槽制作进行全过程质量控制,从而保证电解槽的制作质量和使用效果。
As the concrete made electrolyte cell has high requirement for anti - permeability and surface finishing and uprightness, which makes it difficult for manufacturing and quality control. This article elaborates how to apply whole - process quality control of concrete made electrolyte cell by introducing as - cast finish concrete technology, so as to achieve good quality electrolyte cell and nice effect.
出处
《铜业工程》
CAS
2009年第3期74-77,共4页
Copper Engineering
关键词
电解槽制作
清水混凝土:质量控制
electrolyte cell manufacturing
as - cast concrete
quality control