1Allen HD, Clark EB, Gutgesell HP, et al. Moss and Adams' heart disease in infants, children, and adolescents. 6th ed. Lippincott Williams & Wilkins:A Wolters Kluwer Company,2001 : 603-617.
2Overell JR, Bone I, Lees KR,et al. Interatrial septal abnormalities and stroke : a meta-analysis of case-control studies. Neurology,2000, 55:1172-1179.
4Carminati M, Chessa M, Butera G, et al. Transcatheter closure of atrial septal defects with the STARFIex device: early results and follow-up. J Interv Cardiol, 2001,14:319.
5Hijazi ZM, Bova MPHS, Rhodes J. Simultaneous transcatheter cloure of two secundum atrial septal defect using the Amplatzer^TM septal occluder. J Interven Cardiology, 1998,11 : 181.
6Thomas KJ, Larry AL, Zahn E, et al. Results of the U.S. multicenter pivotal study of the Helex septal occluder for percautaneous closure of secundum atrial septal defects. J Am Coll Cardiol,2007,49 : 2215 -2221.
7Jux C, Bertram H, Wohlsein P,et al. Interventional atrial septal defect closure using a totally bioresoorbable oceluder matrix: development and preclinical evaluation of the BioSTAR device. J Am Coll Cardiol,2006,48 : 161-169.
10Jose S, Alfonso M, Miguel R, et al. Effectiveness of percutaneous device occlusion for atrial septal defect in adult patients with pulmonary hypertension. Am Heart J, 2002,144:887-880.
5Guerios EE, Bueno RR, Nercolini DC, et comparison between Inoue baUoon and metallic in the treatment of rheumatic mitral stenosis: immediate results and 6-month and 3-year follow-up. Catheter Cardiovasc Interv, 2005, 64:301-311.
6Hijazi ZM, Hakim F, Haweleh AA, et al. Catheter closure of perimembranous ventricular septal defects using the new Amplatzer membranous VSD occluder: initial clinical experience. Cathet Cardiovasc Interv, 2002, 56:508-515.
7Fisher G, Kramer HH, Stieh J, et al. Transcatheter closure of secundum atrial septal defects with new self-centering Amplatzer Septal Occluder[J]. Eur Heart J, 1999,20(7) :541 -549.
8Berger F, Ewert P, Abdul-khaliq H,et al. Percutaneous closure of large atrial septal defects with the Amplatzer septal occluder: Technical overkill or recommendable treatment? [J]. J Interven Cardiol,2001,14(1) :63 - 67.
9Ran PS, Langhough R. Relationship of echocardiographic, shunt flow and angiographic size of the stretched diameter of atrial septal defect [J]. Am Heart J, 1991,122:505 -508.
10Hijazi ZM, Cao Q, Patel HT, et al. Transesophageal echocardio-grophic results of catheter closure of atrial septal defect in children and adults using the Amplatzer device[J]. Am J Cardiol,2000,85:1387 - 1390.