期刊文献+

An improved loopless mounting method for cryocrystallography

An improved loopless mounting method for cryocrystallography
下载PDF
导出
摘要 Based on a recent loopless mounting method, a simplified loopless and bufferless crystal mounting method is developed for macromolecular crystallography. This simplified crystal mounting system is composed of the following components: a home-made glass capillary, a brass seat for holding the glass capillary, a flow regulator, and a vacuum pump for evacuation. Compared with the currently prevalent loop mounting method, this simplified method has almost the same mounting procedure and thus is compatible with the current automated crystal mounting system. The advantages of this method include higher signal-to-noise ratio, more accurate measurement, more rapid flash cooling, less x-ray absorption and thus less radiation damage to the crystal. This method can be extended to the flash-freeing of a crystal without or with soaking it in a lower concentration of cryoprotectant, thus it may be the best option for data collection in the absence of suitable cryoprotectant. Therefore, it is suggested that this mounting method should be further improved and extensively applied to eryocrystallographic experiments. Based on a recent loopless mounting method, a simplified loopless and bufferless crystal mounting method is developed for macromolecular crystallography. This simplified crystal mounting system is composed of the following components: a home-made glass capillary, a brass seat for holding the glass capillary, a flow regulator, and a vacuum pump for evacuation. Compared with the currently prevalent loop mounting method, this simplified method has almost the same mounting procedure and thus is compatible with the current automated crystal mounting system. The advantages of this method include higher signal-to-noise ratio, more accurate measurement, more rapid flash cooling, less x-ray absorption and thus less radiation damage to the crystal. This method can be extended to the flash-freeing of a crystal without or with soaking it in a lower concentration of cryoprotectant, thus it may be the best option for data collection in the absence of suitable cryoprotectant. Therefore, it is suggested that this mounting method should be further improved and extensively applied to eryocrystallographic experiments.
作者 齐建勋 江凡
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第1期212-221,共10页 中国物理B(英文版)
基金 Project supported by the National Natural Science Foundations of China (Grant No. 10674172)
关键词 CRYOPROTECTANT crystal mounting data collection flash cooling cryoprotectant, crystal mounting, data collection, flash cooling
  • 相关文献

参考文献22

  • 1Nienaber V L, Richardson P L, Klighofer V, Bouska J J, Giranda V L and Greer J 2000 Nat. Biotechnol 18 1105.
  • 2Service R F 1999 Science 285 1345.
  • 3Verlinde C L and Hol W G 1994 Structure 2 577.
  • 4Bernal J D and Crowfoot D 1934 Nature (London) 133 794.
  • 5Teng T Y 1990 J. Appl. Cryst. 23 387.
  • 6Garman E F and Schneider T R 1997 J. Appl. Cryst. 30 211.
  • 7Thorne R E, Stum Z, Kmetko J, O'Neill K and Gillilan R 2003 J. Appl. Cryst. 36 1455.
  • 8Kitago Y, Watanabe N and Tanaka I 2005 Acta Cryst. D 61 1013.
  • 9Snell G, Cork C, Nordmeyer R, Cornell E, Meigs G, Yegian D, Jaklevie J, Jin J, Stevens R C and Earnest T 2004 Structure 12 537.
  • 10Hope H 1988 Acta Cryst. B 44 22.

相关作者