盐酸依匹斯汀PVC膜电极的研制及应用 被引量:1

Preparation and application of the PVC membrane epinastine hydrochloride selective electrode
下载PDF
导出
摘要 以四苯硼酸钠与盐酸依匹斯汀生成的离子缔合物为电活性物质,研制了盐酸依匹斯汀PVC膜选择性电极。在pH 5的HCl-NaOH溶液中,电极的线性范围为6.3×10-7~1.0×10-1mol/L,斜率为49 mV/pC(10℃),检出限为1.89×10-7mol/L。应用此电极测定药物中盐酸依匹斯汀含量,RSD<3%,回收率为97.5%~100.2%。 A PVC membrane selective electrode was prepared.The ion-associate of epinastine hydrochloride with sodium tetraphenylborate was used as the membrance carrier. The electrode shows a linear Nernst response in the range of 6.3×10-7~1.0×10-1 mol/L and the slope is 49 mV/pC,and the detection limit is 1.89×10-7 mol/L in hydrochloric acid-sodium hydroxide buffer solution of pH 5.0 at 10 ℃.This electrode exhibits a quick response with good reproducibility.It was successfully applied to the determination of epinastine hydrochloride in drugs. The relative standard deviation is less than 3%, and the recoveries are 97.5% - 100.2%. The results are reliable.
出处 《分析试验室》 CAS CSCD 北大核心 2010年第1期44-46,共3页 Chinese Journal of Analysis Laboratory
基金 重庆市自然科学基金(CSTC2007BB7215)项目资助
关键词 盐酸依匹斯汀 PVC膜电极 研制 应用 Epinastine hydrochloride PVC membrane electrode Preparation Application