摘要 某港埠公司M16-25门机的两个电缆卷筒安装位置不佳,容易发生船舶碰撞事故,其减速器与电动机之间也时常发生链条脱落、断开故障和导缆滑轮卡死现象,经过改变安装位置、重新选择电缆卷筒等改造,消除了设备存在的安全隐患,提高了运行性能,降低了维修费用。 As for M16-25 Gantry Crane in a Port Corporation, the two cable reels installed are not at the right position, which easily causes ship collision accident o The speed reducer and the electric motor often break down, such as : The chain often oceurrs off or is out of order; the cable pulley failures and choked o After changing the installed position, using a new method to change cable reel and other transformation, we eliminate the existence of the security risks of the equipment, improve the operational performance, and lower the maintenance costs.
作者 潘伟华
出处 《装备制造技术》 2010年第1期166-168,共3页 Equipment Manufacturing Technology
关键词 门机 电缆卷筒 船舶碰撞 改造 gantry crane cable reel collide transform