摘要
通过135MW循环硫化床机组一次调频试验,分析该类型的机组一次调频性能指标。此次试验体现了循环硫化床机组的特性,也为机组运行提供了一次丰富的实际运行参数,为今后电厂经济运行提供了重要保障。
Through the primary frequency regulation test on 135MW circulating fluidized bed units,analyzes the performance index of the primary frequency regulation for the same type units.The test shows the characteristic of the circulating fluidized bed units,provides lots of practical operating parameter for the units operation,and offers important guarantee for future economic operation for the power plant.
出处
《宁夏电力》
2009年第6期39-41,68,共4页
Ningxia Electric Power
关键词
一次调频
电网频率
硫化床
主汽压力
机组负荷
the primary frequency regulation
power grid frequency
circulating fluidized bed
main steam turbine pressure
units load