摘要
本文使用美国PAR公司EGΣG384B多功能极谱仪建立了SWV法测定辉长石中微量钒的方法。Na2O2溶样、水浸溶块、HAc-NaAc体系,起始电位-0.50V,终止电位-1.50V,钒峰电位-1.04V,灵敏度比经典极谱法提高2个数量级,在所选测定体系条件下,钒峰高随浓度增大而明显增高,且峰电位再现性好、峰形稳定,并用该法对实际样品测定,效果满意。
The article builded method on detemined trace vanadium in minera use ΕGΣG 384B multifuoction made by PAK company of American. The sample treated with Na 2O 2 was at 600℃ in stove. HAc NaAc system was chosen. Initial E-0.500V,Final E-1.500V, Vanadium peak E-1.04V. The sensitivity highest two index number that ordinary voltammetry. The chosen system has produced ideal effect: the peak height of vanadium obviously rises with the concentration of Vanadium, and the identicalness of the peak is satisfactory.
出处
《云南师范大学学报(自然科学版)》
1998年第1期74-77,共4页
Journal of Yunnan Normal University:Natural Sciences Edition
关键词
方波伏安法
微量元素
钒
辉长石
测定
square wave voltammetry trace eleament vanadium peak E