期刊文献+

变压器局放监测抗干扰的多端调节-定向耦合差动平衡法研究 被引量:5

A Method of Multi Adjustment and Directional Difference Balance to Suppress Interference in On Line PD Monitoring of Transformer
下载PDF
导出
摘要 本文根据对大型电力变压器绕组的传输特性的实验研究,提出了应用于大型电力变压器局部放电在线监测中的多端调节-定向耦合差动平衡消除干扰的新方法,建立了相应的电路模型,在理论上进行了详细的分析,并用实验数据证明了该方法的正确性和实用性。 According to the testing result about transmitting characteristics of windings in large capacity transformer,this paper described a new kind of method,multi adjustment and directional difference balance to supperss interference in on line PD monitoring.Furthermore,this paper established the relevant circuit model and made theoretic analysis in detail.At last,the testing data confirmde that the method was proper and practicable.
机构地区 重庆大学
出处 《电工技术学报》 EI CSCD 北大核心 1998年第5期47-51,共5页 Transactions of China Electrotechnical Society
关键词 电力变压器 局部放电 抗干扰 差动平衡法 变压器 Transformer PD Multi adjustment and directional difference balance Adjustable suppressor of interference
  • 相关文献

参考文献5

  • 1罗兵,博士学位论文,1996年
  • 2邱昌容,电工设备局部放电及测试技术,1994年
  • 3Su Q,IEEE Proc C,1992年,139卷,5期
  • 4葛景滂,局部放电测量,1984年
  • 5万达,局部放电论文集

同被引文献54

引证文献5

二级引证文献55