期刊文献+

碳纳米管组装电极上电化学分析法测定1-萘酚的研究

Electrochemical Determination of 1-naphthol at a Glassy Carbon Electrode Modified with Multiwall Carbon Nnanotubes
下载PDF
导出
摘要 以碳纳米管修饰玻碳电极为工作电极,研究了碳纳米管修饰玻碳电极和玻碳电极上1-萘酚的电化学行为,建立了计时电流法测定1-萘酚的电化学分析新方法。对测定条件进行了详细的研究,在最佳实验条件下,响应电流与1-萘酚的浓度在1.0×10-6~3.0×10-3 mol·L-1范围内呈良好的线性关系,检出限为4.0×10-7 mol·L-1。 A simple and highly sensitive amperometric method for the determination of 1-naphthol has been developed at a glassy carbon electrode modified with multiwall carbon nanotubes(MWNT).The electrochemical behaviors of 1-naphtol at a bare glass carbon electrode and a MWNT modified glass carbon electrode were investigated and the determined conditions were optimized in details.Under the optimized conditions,the oxidation currents on a MWNT-modified glassy carbon electrode at a applied potential of 0.30 V is linear over a range from 1.0×10-6~3.0×10-3 mol·L-1 1-naphthol with the detection limit of 4.0×10-7 mol·L-1 1 -naphthol.
作者 李小蓉 张拴
出处 《咸阳师范学院学报》 2009年第6期38-40,共3页 Journal of Xianyang Normal University
关键词 1-萘酚 多壁碳纳米管 电化学 1-naphthol multiwall carbon nanotubes electrochemical
  • 相关文献

参考文献9

  • 1Daghbouche Y, Garrigues S, Guardia M. Solid phase preconcentration-Fourier transform infrared spectrometric determination of carbaryl and 1-naphthol[J]. Anal Chim Acta,1995, 314 (3): 203-212.
  • 2于成峰.高效液相色谱法测定染发剂中α-萘酚[J].化学世界,2000,41(2):101-103. 被引量:13
  • 3Massey K A, Engelen D L, Warner I M.Determination of carbaryl as its metabolite, 1-naphthol, by reversed-phase high-performance liguid chromatography with fluorometric detection [J]. Talanta, 1995, 42 (10):1457-1463.
  • 4Wu F H, Zhao G C, Wei X W.Electrocatalytic oxidation of nitric oxide at multi-walled carbon nanotubes modified electrode [J]. Electrochemistry Communications, 2002, 4 (9): 690-694.
  • 5Zhao Q, Gu Z N, Zhuang Q K.Electrochemical study of tetra-phenyl-porphyrin on the SWNTs film modified glassy carbon electrode [J]. Electrochemistry Communications, 2004, 6 (1):83-86.
  • 6Wang J X, Li M X, Li N Q, et al. Electrocatalyfic oxidation of 3,4-dihydroxyphenylaeetic acid at a glassy carbon electrode modified with single-wall carbon nanotubes [J]. Electrochimi Acta, 2001,47 (4): 651-657.
  • 7Mustafa M, Joseph W, Merkoci A, et al, Low-potential stable NADH detection at carbon-nanotube-modified glassy carbon electrodes [J].Electrochemistry Communications, 2002,4 (10): 743-746.
  • 8Joseph W, Mustafa M. Carbon nanotube/teflon composite electrochemical, sensors and biosensors[J]. Anal Chem, 2003, 75 (9):2075-2079.
  • 9Daghbouche Y, Garrigues S, Guardia M.Solid phase preconcentration-Fourier transform infrared spectrometric determination of carbaryl and 1-naphthol[J]. Anal Chim Acta, 1995, 314 (3):203-212.

二级参考文献1

  • 1郑星泉.化妆品卫生检验[M].天津:天津大学出版社,1988.32.

共引文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部