摘要 中央空调能耗在现代楼宇建筑总能耗中所占比例很高,对其进行节能改造意义重大。本方案将空压站循环冷却水的剩余热量换热至办公区空调制热系统,用于冬季供暖,实现了能源的循环利用,节约了大量资金,有较好的推广前景。 Since energy consumption of central air conditioner occupies a fairly large portion of total energy consumption in modem buildings,energy saving reconstrction for it is necessary. In this paper, remaining heat of cooling circulating water of the air compressor station is transferd to air conditioner's heating system in office area for heating in the winter.Recycling utilization of energy is realized through this system; meanwhile massive funds have been saved.That has good popularizing prospect.
出处 《中国造船》 EI CSCD 北大核心 2009年第A11期476-478,共3页 Shipbuilding of China
关键词 中央空调节能 空压站余热 冷却循环水 供暖 energy saving of central air conditioner waste heat of air compressor station cooling circulatingwater heating