摘要
阐述LNG汽车加气站的一般规模及构成,分析LNG汽车加气站与LPG汽车加气站、LNG气化站在气源的特性、厂站的建设规模等方面的差异,根据相关现行的国内、外设计规范,探讨LNG汽车加气站消防设计方案。
The general scale and composition of LNG vehicle filling station are expounded. The differences among LNG vehicle filling station, LPG vehicle filling station and LNG vaporizing station are analyzed in terms of gas source characteristics, station construction scale and so on. According to the relevant current domestic and foreign design codes, the fire control design scheme of LNG vehicle filling station is discussed.
出处
《煤气与热力》
2010年第1期39-41,共3页
Gas & Heat
关键词
LNG汽车加气站
消防设计
LPG汽车加气站
LNG气化站
LNG vehicle filling station
fire control design
LPG vehicle filling station