摘要
简述了湛江电力有限公司#1、#2机组由于燃料市场变化被迫燃烧非设计煤种的工况下,针对机组原CCS控制策略无法适应此锅炉燃烧工况,导致机组无法投入AGC方式运行的问题。提出了相应的控制策略优化解决方案。
In this paper, the condition on # 1-2 unit of Zhanjiang Electric Power Co., Ltd. dueing to the change of fuel market to bum the unspecified fuel is introduced. According to the original CCS control strategy that can not adapt to the boiler combustion conditions to result in running problems in AGC Unit., the corresponding control strategy optimization solutions is put forward.
出处
《自动化与仪器仪表》
2010年第1期122-122,125,共2页
Automation & Instrumentation
关键词
非设计煤种
AGC
协调控制
控制策略
优化
Unspecified coal
AGC
Cooperative control
Control strategy
Optimization