期刊文献+

井地电位监测技术现场试验结果对比分析 被引量:3

Comparative analysis of field test results of well-ground potential monitor technology.
下载PDF
导出
摘要 文章简要介绍了井地电位测量技术的方法原理和现场施工步骤,重点针对三套不同井地电位监测系统在喇嘛甸油田北西块6区的喇6-233和喇6-P2325两口井的现场试验结果进行了对比分析发现,监测结果的一致性较高;再结合三套监测系统的主要技术指标表明,发射电流的大小以及选择合适的发射频率对井地电位监测的精度、探测深度起到比较关键的作用。 This paper introduces the methodological principle of the well-ground potential monitoring technique and on-site construction procedure briefly,and comparatively analyses two well field test results by three set well-ground potential surveillance system in La6-233 well and La6-p2325 well of area 6 of the north west block in Lamadian oilfield. Consistency of monitoring result is well. Three set monitoring system technical description shows that emission current magnitude and the selected appropriate transmission frequency play key role in well-ground potential monitor accuracy and investigation depth.
作者 吕德彬
出处 《石油仪器》 2009年第6期60-62,10,共3页 Petroleum Instruments
关键词 井地电位 发射电流 频率 well-ground potential emission current frequency
  • 相关文献

参考文献3

二级参考文献20

  • 1潘种祥 高纪清 等.石油地质学[M].地质出版社(北京),1986..
  • 2HOVERSTEN G M,et al.Reservoir characterization using crosswell electromagnetic inversion,a feasibility study for the Snorre field,North Sea [J].Geophysics,2001,66(4):1177-1189 .
  • 3ALUMBAUGH D L,NEWMAN G A,et al.Three-dimensional wideband electromagnetic modeling on massively parallel computers[J].Radio Science,1996,31(1):1-23.
  • 4TSENG H W,BECKER Alex,et al.Borehole-to-surface electromagnetic survey[J].Geophysics,1998,63(5):1565-1572.
  • 5ROCROI J P and KOULOKOV A V.The use of vertical line sources in electrical prospecting for hydrocarbon[J].Geophysical Prospecting,1985,33:138-152.
  • 6SILL W R and WARDS S H.Electrical energizing of well casings[R].Univ of Utah Dept of Geol And Geophys,Contract EY-76-3-07-1601,1978.7-78.
  • 7KEISUKE U,HIDEKI M,et al.Reservoir monitoring by 4-D electrical technique[J].The Leading EDGE,1999,6:141-143.
  • 8RANGANAYAKI R P,AKTURK S E and FRYER S M.Formation resistivity variation due to steam flooding:a log study[J].Geophysics,1992,57(3):488-494.
  • 9MANSURE A J,MELDAU R F and WEYLAND H V.Field examples of electrical resistivity changes during steamflooding[J].SPE Formation Evaluation,1993,8(1):57-64.
  • 10KAUFMAN A A and WIGHTMAN W E.Transmission-line model for electrical logging through casing[J].Geophysics,1993,58(12):1739-1747.

共引文献27

同被引文献13

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部