期刊文献+

Influence of galvano-ceramic and metal-ceramic crowns on magnetic resonance imaging 被引量:6

Influence of galvano-ceramic and metal-ceramic crowns on magnetic resonance imaging
原文传递
导出
摘要 Background Magnetic resonance imaging (MRI) is prone to be deformed by artifacts caused by the presence of metallic materials. The aim of this study was to evaluate the artifacts from galvano-ceramic and metal-ceramic crowns in MRI, in order to analyze their influences on diagnostic interpretation of MRI. Methods Galvano-ceramic and metal-ceramic crowns (Bio98, Wiron99, SP-78, BioKC97) were fabricated with the same model. All materials were imaged by means of 1.5T MRI apparatus with three different sequences, T1-weighted spin-echo (T1-weighted SE), T2-weighted spin-echo (T2-weighted SE) and Gradient echo (GE). Mean and standard deviation of distilled water signal intensity (St) around the sample in the region of interest (500 mm^2) enclosing the whole artifacts were determined, and compared for evaluation of the homogeneity of signal intensity. Images around the sample were acquired and evaluated. Results There were statistically significant differences in the values of signal intensity between acrylic resin control and BioKC97, Wiron99 in the three sequences (P〈0.001). The mean values of signal intensity for Bio98, SP-78 were significantly different from that of acrylic resin control (RE) in GE sequence (P〈0.001). No difference was showed between acrylic resin control and galvano-ceramic crown (P 〉0.05). Images showed that the greatest artifact was a 25 mm ring with distortion in Wiron99 in GE sequence. Conclusions This in vitro study suggested that galvano-ceramic crown had no influence on the MRI, while metal-ceramic crowns caused moderate artifacts in the MRI. Therefore, galvano-ceramic restoration is a valuable alternative in dentistry. Background Magnetic resonance imaging (MRI) is prone to be deformed by artifacts caused by the presence of metallic materials. The aim of this study was to evaluate the artifacts from galvano-ceramic and metal-ceramic crowns in MRI, in order to analyze their influences on diagnostic interpretation of MRI. Methods Galvano-ceramic and metal-ceramic crowns (Bio98, Wiron99, SP-78, BioKC97) were fabricated with the same model. All materials were imaged by means of 1.5T MRI apparatus with three different sequences, T1-weighted spin-echo (T1-weighted SE), T2-weighted spin-echo (T2-weighted SE) and Gradient echo (GE). Mean and standard deviation of distilled water signal intensity (St) around the sample in the region of interest (500 mm^2) enclosing the whole artifacts were determined, and compared for evaluation of the homogeneity of signal intensity. Images around the sample were acquired and evaluated. Results There were statistically significant differences in the values of signal intensity between acrylic resin control and BioKC97, Wiron99 in the three sequences (P〈0.001). The mean values of signal intensity for Bio98, SP-78 were significantly different from that of acrylic resin control (RE) in GE sequence (P〈0.001). No difference was showed between acrylic resin control and galvano-ceramic crown (P 〉0.05). Images showed that the greatest artifact was a 25 mm ring with distortion in Wiron99 in GE sequence. Conclusions This in vitro study suggested that galvano-ceramic crown had no influence on the MRI, while metal-ceramic crowns caused moderate artifacts in the MRI. Therefore, galvano-ceramic restoration is a valuable alternative in dentistry.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2010年第2期208-211,共4页 中华医学杂志(英文版)
关键词 magnetic resonance imaging galvano-ceramic metal-ceramic ARTIFACT magnetic resonance imaging galvano-ceramic, metal-ceramic artifact
  • 相关文献

参考文献1

二级参考文献11

  • 1吴胜勇,尉传社.3.0TMR成像系统的优势及其在中枢神经系统中的应用[J].医学综述,2005,11(1):93-95. 被引量:4
  • 2周诚.重视CT、MRI腹部检查技术的应用[J].中华医学杂志,2005,85(5):289-290. 被引量:6
  • 3Gray CE, Redpath TW, Smith FW, et al. Advanced imaging: magnetic resonance imaging in implant dentistry: a review. Clin Oral Implants Res, 2003, 14: 18-27.
  • 4Kuhl CK, Traber F, Schild HH, et al. Whole-body high-field-strength (3. 0-T ) MR imaging in clinical practice part Ⅰ. Technical considerations and clinical applications. Radiology, 2008, 246:675-696.
  • 5Lissac M, Metrop D, Brugirard J , et al. Dental materials and magnetic resonance imaging. Invest Radiol, 1991,26:40-45.
  • 6Hubalkova H, Hora K, Seidl Z, et al. Dental materials and magnetic resonance imaging. Eur J Prosthodont Restor Dent, 2002, 3: 125-130.
  • 7Abbaszadeh K, Heffez LB, Mafee MF, et al. Effect of interference of metallic objects on interpretation of T1 -Wighted magnetic resonance images in the maxillofacial region. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2000, 89:759-765.
  • 8Burtscher IM, Owman T, Romner B, et al. Aneurysm clip MR artifacts: titanium versus stainless steel and influence of imaging parameters. Acta Radiol, 1998, 39 : 70-76.
  • 9Olsrud J, Latt J, Brockstedt S, et al. Magnetic resonance imaging artifacts caused by aneurysm clips and shunt valves: dependence on field strength ( 1.5 and 3 T) and imaging parameters. J Magn Reson Imaging, 2005, 22:433-437.
  • 10Meindl T, Born C, Britsch S, et al. Functional BOLD MR.I: comparison of different field strengths in a motor task. Eur Radiol, 2008, 18:1102-1113.

共引文献6

同被引文献30

  • 1解春,俞立英,林江,刘含秋.常用口腔金属修复材料在不同场强MRI上的伪影检测与比较[J].复旦学报(医学版),2007,34(6):915-917. 被引量:3
  • 2王威,姜波,吴宣,孙建军.三种烤瓷合金材料对磁共振成像的影响[J].中国医学科学院学报,2010,32(3):276-279. 被引量:5
  • 3王威,姜波,金阳,吴萱,陈新.镍铬合金对3.0T与1.5T磁共振成像的伪影分析[J].中国医药导报,2007,4(07S):124-125. 被引量:9
  • 4肖云,姚江武,郭珍珍,张有彬,庄雄杰.桩钉对磁共振成像伪影形成的影响[J].口腔医学研究,2007,23(4):448-450. 被引量:4
  • 5TominagaT,ShimizuH,etal.Magneticresonanceimagingoftitaniumanteriorcervicalspinepaltingsystems. Neurosurgery . 1995
  • 6RothCK,TalbotJ.MRIinpractice. . 2005
  • 7Bernstein Matt A,Huston John,Ward Heidi A.Imaging artifacts at 3.0T. Journal of magnetic resonance imaging : JMRI . 2006
  • 8Harris T M J,Faridrad M R,Dickson J A S.The benefits of aesthetic orthodontic brackets in patients requiring multiple MRI scanning. Journal of Orthodontics . 2006
  • 9Kaneda T,Minami M,Curtin H D,Utsunomiya T,Shirouzu I,Yamashiro M,Kiba H,Yamamoto H,Ohba S.Dental bur fragments causing metal artifacts on MR images. AJNR. American journal of neuroradiology . 1998
  • 10Comparison of cone-beam computerized tomography and intraoral radiographs for determination of the periodontal ligament in a variable phantom(J)Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and Endodontology . 2010 (2)

引证文献6

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;