SynCone套筒冠式即刻负重种植系统的固位特性研究 被引量:3

Study of the retentive characteristics for SynCone conical crown immediate loading system
下载PDF
导出
摘要 目的:实验室研究SynCone套筒冠式即刻负重种植系统的固位特性。方法:选取锥度为4度和6度的SynCone直基台套筒冠系统各6个作为研究对象,采用Life-test仪器,在20N就位力的条件下重复测量其固位力5000次,分析其固位力的大小及其持久性。结果:在20N就位力条件下,4度锥度的SynCone套筒冠系统的固位力均数为8.01N,6度锥度的套筒冠系统的固位力均数为7.23N;两种锥度套筒冠的固位力无显著性差异,固位力持久。结论:SynCone套筒冠即刻负重种植系统可为其上的覆盖义齿提供适宜持久的固位力。 To study of the retentive characteristics for SynCone conical crown immediate loading system. Methods:6 SynCone conical crowns with 4-degree angle and 6 SynCone conical crowns with 6-degree angle were tested in vitro for a total of 5000 insertion-separation cycles to investigate their retentive characteristics under 20N insertion force. Their retentive characteristics were analyzed. Results: Under 20 N insertion force, the retentive force of SynCone conical crown system was between 5 and 10 N. The retentive force kept almost constant during the entire testing cycles. Conclusion: the SynCone conical crown system can provide adequate and constant retentive force to retain implantsupported overdentures.
出处 《中国口腔种植学杂志》 2009年第4期101-104,共4页 Chinese Journal of Oral Implantology
基金 国家留学基金资助项目 项目号22832068
关键词 套筒冠 固位特性 覆盖义齿 种植牙 conical crown, retentive characteristic, overdenture, dental implant
  • 相关文献

参考文献16

  • 1Chiapasco M, Abati S, Romeo E. et al. Implant-retained with o Branemark mandibular overdentures System MKII implants: a prospective comparative study between de layed and immediate loading. Int. J. Oral Maxillofac. Implants., 2001; 16:537-546.
  • 2Romeo E, Chiapasco M, Lazza A. et al. Implant-retained mandibular overdentures with ITI implants. Clin. Oral. Implants. Res., 2002; 13: 495-501.
  • 3Gatti C and Chiapasco M. Immediate loading o of Branemark implants: a 24-month follow-up of a comparative prospective pilot study between mandibular overdentures supported by conical transmucosal and stan-dard MKII implants. Clin. Implant. Dent. Relat. Res., 2002; 4: 190-199.
  • 4Lorenzoni M, Perti C, Zhang K. Et al. In-patient comparison of immediately loaded and non-loaded implants within 6 months. Clin. Oral. Implants. Res., 2003; 14: 273-279.
  • 5Chiapasco M and Oatti C. Implant-retained mandibular overdentures with immediate loading: a 3- to 8-year prospective study on 328 implants. Clin. Implant. Dent. Relat. Res., 2003; 5: 29-38.
  • 6May D and Romanos GE. Immediate implant-supported mandibular overdentures retained by conical crowns: A new treatment concept. Quintessence. Int., 2002; 33: 5-12.
  • 7Ohkawa S, Okane H, Nagasawa T. et al. Changes in retention of various telescope crown assemblies over long-term use. J. Prosthet. Dent,, 1990; 64: 153-158.
  • 8Besimo CH, Graber G, and Flu hler M. Retention force changes in implant-supported titanium telescope crowns over long-term use in vitro. J. Oral. Rehabil, 1996,23:372-378.
  • 9Minagi S, Natsuaki N, Nishigawa G. et al. New telescopic crown design for removable partial dentures. J. Prosthet. Dent., 1999,81: 684-688.
  • 10Gungor MA, Artunc C and Sonugelen M. Parameters affecting retentive force of conus crowns. J. Oral. Rehabil, 2004,31: 271-277.

同被引文献39

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部