摘要 应用ANSYS软件获得了门式刚架半刚性端板连接节点在高温下的转角—温度关系曲线及其临界温度,探讨了端板厚度、高强度螺栓规格、加劲肋厚度、摩擦系数、端板摆放位置等组件的变化对临界温度和节点转角一温度关系曲线的影响.为了提高半刚性梁柱连接节点的抗火性能,节点各组件的尺寸或规格需要相互匹配,以免某个组件过早屈服或断裂而导致连接节点失效,特别要注意端板、柱内侧翼缘、螺栓直径之间的匹配. The critical temperature of the semi-rigid end-plate connection about gabled frame and rotation-temperature relationship curves of the connection were obtained by ANSYS software; Then the influences of several parameters on the behavior of connection in fire were also investigated, for instance, the thickness of end-plate, the diameters of high strength bolts, the thickness of stiffeners, friction factor, the place of end-plate. In order to improve the resistence fire property about the beam and column of the semi-rigid end-plate joint, the sizes and the items of the joint's component must match each other, which avoid any component buckling and breaking in advance, then lead to the joint's breakage, especially we'll pay attention to the end- plate, the inner flang of the column, the diameters of high strength bolts matching each other.
出处 《浙江工业大学学报》 CAS 北大核心 2010年第1期98-101,共4页 Journal of Zhejiang University of Technology
关键词 半刚性端板节点 转角-温度关系 临界温度 有限元分析 semi-rigid end-plate joint rotation-temperature relationship critical temperature finite element analysis
  • 相关文献

参考文献3

二级参考文献7

共引文献7

同被引文献17

  • 1Ding J, Wang Y C. Experimental study of structural fire behaviour of steel beam to concrete filled tubular column assemblies with different types of joints [J]. Engineering Structures, 2007, 29(12): 3485--3502.
  • 2Al-Jabri K S, Davison J B, Burgess I W. Performance of beam-to-column joints in fire-A review [J]. Fire Safety Journal, 2008, 43(1): 50--62.
  • 3Qiang X H, Bijlaard Frans S K, Kolstein H, Jiang X. Behaviour of beam-to-column high strength steel endplate connections under fire conditions-Part 1: Experimental study [J]. Engineering Structures. 2014, 64: 23--38.
  • 4A1-Jabri K S, Seibi A, Karrech A. Modelling of unstiffened flush end-plate bolted connections in fire [J]. Journal of Constructional Steel Research, 2006, 62(1/2): 151--159.
  • 5Qiang X H, Bijlaard Frans S K, Kolstein H, Jiang X. Behaviour of beam-to-column high strength steel endplate connections under fire conditions - Part 2: Numerical study [J]. Engineering Structures, 2014, 64: 39--51.
  • 6Qiang X, Bijlaard F, Kolstein H, Twilt L. Numerical modelling of HSS endplate connections at elevated temperatures [C]. East Lansing, MI: Destech Publications, Inc, 2010:671--678.
  • 7Yu H, Burgess I W, Davison J B, et al. Experimental and numerical investigations of the behavior of flush end plate connections at elevated temperatures [J]. Journal of Structural Engineering, 2011,137(1): 80--87.
  • 8ABAQUS Inc. ABAQUS Analysis User's Manual Version 6.5 [M]. Providence: ABAQUS Inc. 2004.
  • 9BS EN 1993-1-2, Eurocode 3: Design of steel structures, Part 1.2: General rules-Structural fire design [S]. London: British Standards Institution, 2005.
  • 10Yu H, Burgess I W, Davison J B, et al. Numerical simulation of bolted steel connections in fire using explicit dynamic analysis [J]. Journal of Constructional Steel Research, 2008, 64(5): 515--525.

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部