期刊文献+

自保温混凝土叠合承重墙结构体系研究 被引量:3

Study on Insulating Concrete Composite Bearing Wall Structure System
下载PDF
导出
摘要 自保温混凝土叠合承重墙可以解决长期存在的传统建筑外墙保温的难题。这种墙体通过内贴保温层(聚苯板)的混凝土预制板,再和现浇混凝土柱连接而成。该墙体具有整体性好、施工快、保温隔热性好等特性。在弹性阶段,预制板和隐形框架可很好的协同工作,形成一个整体;弹塑性阶段,预制板随着裂缝的开展而逐步退出工作;墙体最后退化为由预制板边肋和隐形框架组成的密柱叠合框架;预制板和隐形框架两者可形成两道抗震设防。因此自保温混凝土叠合承重墙体具有较大的承载力、良好的抗震性能和延性。 The long-standing problem of the external wall thermal insulation of the building can be solved by the concrete composite bearing wall structure system. The wall mainly is composed of prefabricated slabs with polystyrene inside and contact framework is the main strength component of the concrete composite beating wall housing. The wall has good holistie capability, swift constructing and good energy saving capability. In the elastic stage, the prefabricated board and frame could work in coordination very well; In the elastic-plastic stage, prefabricated slabs gradually quit work; Two seismic fortifications can be formed by them. It is shown that the wall had good load-carrying capacity, seismic behavior and ductility.
出处 《江苏建筑》 2010年第1期24-25,79,共3页 Jiangsu Construction
关键词 混凝土叠合承重墙 预制板 延性 隐形框架 concrete composite bearing wall prefabricated board ductility stealthy frame
  • 相关文献

参考文献3

  • 1GB50011-2008建筑抗震设计规范[S].中国建筑工业出版社.
  • 2张伟杰.混凝土叠合承重墙的试验研究[D].东南大学,2008.
  • 3丁大钧.墙体改革与可持续发展[J].建筑结构,2004,34(3):56-62. 被引量:23

二级参考文献27

  • 1.混凝土小型空心砌块建筑技术规程(JGJ/T14—95)[M].北京:中国建筑工业出版社,1995..
  • 2.江苏省结构构造通用图集:小型空心砌块框架填充墙构造图集(苏G9409)[M].,1994..
  • 3章关福.[D].上海中房建筑设计院,1998.
  • 4翟希梅.[D].哈尔滨工业大学,2002.
  • 5.砌体结构设计规范(GB50003-2001)[M].北京:中国建筑工业出版社,2002..
  • 6上海钟宏科技发展有限公司.产品块型图表[M].,..
  • 7上海市房屋建筑设计院.[D].,2000.
  • 8(DBJ/CT009-2001).上海市建筑产品推荐性应用标准:混凝土多孔砖建筑技术规程.[S].,2001..
  • 9南京旭建新型建筑材料有限公司.New Building Materials[M].,2002..
  • 10.江苏省建筑配件通用图集:蒸压轻质加气混凝土(ALC)板构造图集(苏J01-2002)[M].,..

共引文献22

同被引文献23

引证文献3

二级引证文献2