期刊文献+

加热炉排烟系统烟气偏流原因分析与对策

Analysis and treatment of asymmetric gas in reheating furnace
下载PDF
导出
摘要 针对鞍钢1700ASP生产线2号加热炉排烟系统烟气偏流问题,对烟道结构和换热器结构特点进行技术分析,并采用热工测试手段找出了煤气换热器局部漏损原因。具体为外部烟气流量大、内部煤气分流不均、气体流量小等。并提出了改烟闸为双轴双板结构,风箱安装分流板,增加空气换热器换热面积的应对策略。 A technological analysis was done for gas pipe and heat transfer focused on asymmetric gas problem of No. 2 reheating furnace in Ansteel 1700ASP rolling line . The cause of gas heat transfer leakage, that a mass of outlet gas, uneven distributed gas before heat transfer and not enough gas flow, was found by thermal test. The treatments including changing the gas door to 2 - roll - 2 - ban style and installing the divergence board and increasing the heat transfer area of air heat transfer were promoted.
出处 《冶金能源》 2010年第1期32-34,共3页 Energy For Metallurgical Industry
关键词 加热炉 烟气偏流 换热器 reheating fumaee asymmetric gas heat transfer
  • 相关文献

参考文献2

  • 1陆钟武 宁宝林.工业炉热工及构造[M].沈阳:东北大学,1983..
  • 2陆钟武.火焰炉[M].北京:冶金工业出版社,1994.

共引文献15

相关作者

内容加载中请稍等...

相关机构