基于小电晕笼的高海拔电晕损失测量系统的研究 被引量:4

High Altitude Corona Loss Measurement System Based on Small Corona Cage
下载PDF
导出
摘要 为了研究不同海拔高度下导线起晕电压特性,应用小电晕笼,结合光纤传输技术,基于虚拟仪器技术,研制出一套光纤数字化高海拔电晕损失测量系统。在试验过程中,通过逐渐升高电压使试验导线起晕,应用该系统对其电晕损失进行测量。可以通过在不同的海拔点测量几种导线的电晕损失,作为不同海拔高度导线起晕电压的判断依据,进行导线起晕电压海拔修正方面的研究。试验结果表明,研制的小电晕笼电晕损失测量系统是准确可行的,同时由于中国交流特高压建设途经高海拔地区的特点,也可以考虑应用该系统进一步研究不同气压、温度、湿度等因素对导线电晕损失值的影响,为中国交流特高压输电线路电晕损失规律的进一步研究打下基础。 In order to investigate corona inception voltage characteristic of transmission lines at different altitudes, a fiber-digital high altitude corona loss measurement system was developed on the basis of virtual instrument technology, optical fiber transmission technology, and small corona cage. Experiment was conducted by gradually increasing voltage to induce corona inception on transmission lines, and measuring the corona loss with this system. Experimental result shows that this corona loss measurement system is accurate and feasible. Experiments ought to be conducted at different altitudes to achieve the relation between corona inception voltage and altitude. The measurement system can be used to further study the influences of air pressure, temperature, humidity on corona loss.
出处 《高压电器》 CAS CSCD 北大核心 2010年第2期35-38,41,共5页 High Voltage Apparatus
基金 国家科技支撑计划(2006BAA02A04) 1000kV交流输变电工程线路及变电站设备电晕特性研究
关键词 电晕笼 高海拔 电晕损失 测量系统 corona cage high altitude corona loss measurement system
  • 相关文献

参考文献5

二级参考文献29

  • 1焦尚彬,刘丁,郑岗,李琦.基于遥测技术的输电线路绝缘子污秽在线监测系统[J].电力系统自动化,2004,28(15):71-75. 被引量:26
  • 2毛文奇,刘海燕,徐华,黄文武.特高压输电对环境影响的讨论[J].电力建设,2004,25(8):54-56. 被引量:28
  • 3虞菊英.我国特高压交流输电研究现状[J].高电压技术,2005,31(12):23-25. 被引量:52
  • 4关志成,张福增,王国利,龙彪,王黎明.我国特高压的特有技术问题[J].电力设备,2006,7(1):1-4. 被引量:40
  • 5赵秀山,谈克雄,朱德恒,李福祺.介质损耗角的数字化测量[J].清华大学学报(自然科学版),1996,36(9):51-56. 被引量:44
  • 6Comber M C,Zaffanella L E.The use of single phase overhead test lines and test cages to evaluate the corona effects of EHV and UHV transmission line[J].IEEE Trans on Power Appar Syst,1974,93(1):81-90.
  • 7Scherer H N Jr,Vassell G S.Transmission of electric power at ultra-high voltages:current status and future prospects[J].Proceedings of the IEEE,1985,73(8):1252-1278.
  • 8Giao Trinh N,Sarma Maruvada P,Benny Poirier.A comparative study of the corona performance of conductor bundles for 1200 kV transmission lines[J].IEEE Trans on Power Appar Syst,1974,93 (3):940-949.
  • 9Nakano Y,Sunaga Y.Availability of corona cage for predicting audible noise generated from HVDC transmission line[J].IEEE Trans on PWRD,1989,4(2):1422-1431.
  • 10Nakano Y,Sunaga Y.Availability of corona cage for predicting radio interference generated from HVDC transmission line[J].IEEE Trans on PWRD,1990,5(3):1436-1442.