碰撞/反应池ICP-MS性能及应用进展 被引量:107

The Performance and Application on the Collision/Reaction Cell ICP-MS
下载PDF
导出
摘要 对碰撞/反应池ICP-MS的性能及应用进展进行了综述。碰撞/反应池是目前四极杆ICP-MS首推的,最有效的消除多原子干扰的技术,近年来已经在痕量超痕量多元素分析、形态分析和同位素比值分析中得到很好的应用。预期在今后将继续发挥作用,并扩大其应用范围。 The performance of collision/reaction cell ICP-MS and its application progress were briefly reviewed. The collision/reaction cell technology was widely accepted as the most effective way to minimize or eliminate polyatomic interferences in ICP-MS. The technology was applied to trace and ultra-trace element analysis, speciation and isotope ratio analysis. It is expected to continue to play a role in the future, and will expand its scope of application.
出处 《质谱学报》 EI CAS CSCD 2010年第1期1-11,共11页 Journal of Chinese Mass Spectrometry Society
基金 国家自然科学基金(40773048) 地质大调查项目(1212350816015)资助
关键词 碰撞/反应池 ICP-MS 性能 应用 collision/reaction eell(CRC) ICP-MS performance application
  • 相关文献

参考文献43

  • 1BARANOV V I ,TANNER S D. A dynamic reaction cell for inductively coupled plasma mass spectrometry (ICP-DRC-MS) Part 1. the rf-field energy contribution in thermodynamics of ion-molecule reactions [J]. J Anal At Spectrom, 1999, 14: 1 133-1 142.
  • 2TANNER S D, BARANOV V I. A dynamic reaction cell for inductively coupled plasma mass spectrometry(ICPDRC-MS). Ⅱ. reduction of interferences produced within the cell[J]. J Am Soc Mass Spectrom,1999, 10:1 083-1 094.
  • 3TANNER S D, BARANOV V I, VOLLKOP U. A dynamic reaction cell for inductively coupled plasma mass spectrometry(ICP-DRC-MS)Part Ⅲ. optimization and analytical performance[J]. J Anal At Spectrom, 2000, 15:1 261-1 269.
  • 4BANDURA D R, BARANOV V I, TANNER S D. Detection of ultratrace phosphorus and sulfur by quadrupole ICPMS with dynamic reaction cell [J]. Anal Chem, 2002, 74:1 497-1 502.
  • 5ANICICH V G. A survey of bimolecular ion-molecule reactions for use in modeling the chemistry of planetary atmospheres, cometary comae, and in- terstellar clouds: 1993 supplement[J]. The Astrophysical Journal Supplement Series, 1993, 84 (2) : 215-315.
  • 6KOYANAGI G K, BARANOV V I, TANNER S D, et al. An inductively coupled plasma/selectedion-flow tube mass spectrometric study of the chemical resolution of isobaric interferences[J]. J Anal At Spectrom, 2000, 15; 1 207-1 210.
  • 7BANDURA D R, BARANOV V I, TANNER S D. Detection of ultratrace phosphorus and sulfur by quadrupole ICPMS with dynamic reaction cell [J]. Anal Chem, 2002, 74(7):1 497-1 502.
  • 8MASON P R D, KASPERS K, BERGEN M J. Determination of sulfur isotope ratios and concentrations in water samples using ICP-MS incorporating hexapole ion optics[J]. J Anal At Spectrom, 1999,14:1 067-1 074.
  • 9VANHAECKE F, BALCAEN L, DECONINCK I, et al. Mass discrimination in dynamic reaction cell(DRC)-ICP-mass spectrometry[J]. J Anal At Spectrom, 2003, 18:1 060-1 065.
  • 10BANDURA D R, BARANOV V I, TANNER S D. Effect of collisional damping and reactions in a dynamic reaction cell on the precision of isotope ratio measurements [J]. J Anal At Spectrom, 2000, 15: 921-928.