摘要
建立了使用233U作为同位素稀释剂,流动注射-电感耦合等离子体质谱联用法分离测量土壤样品中铀的方法。土壤样品经过微波消解后,以UTEVA树脂在线预富集铀,0.2 mol.L-1HCl解吸铀,且直接将铀解吸液导入多接收电感耦合等离子体质谱仪测定同位素比,从而得出样品中铀的同位素比及铀的浓度。通过对土壤标准样品的分析,验证了方法的可行性,结果与标称值一致。该方法对238U和235U的检测限分别为5.4×10-9g和5.7×10-11g。
A rapid on-line separation and preconcentration method for the determination of uranium in soil was developed by flow injection multi-collector inductively coupled plasma mass spectrometry(FI-MC-ICP-MS) using 233U as spike for the isotope dilution analysis. The on-line separation was based on uranium adsorption on UTEVA resin. The absorbed uranium was eluted with 0. 2 mol.L^-1 HCl and directly introduced into MC-ICP-MS for measuring uranium isotopes. The method was examined by determining the uranium in soil standard reference materials. The results are in good agreement with the certified values. The limits of detection of ^238U and 235U are 5.4× 10^-9 g and 5.7× 10^11 g.
出处
《质谱学报》
EI
CAS
CSCD
2010年第1期34-38,共5页
Journal of Chinese Mass Spectrometry Society
关键词
铀
微波消解
UTEVA
同位素稀释
多接收电感耦合等离子体质谱
在线分离预富集
uranium
microwave digestion
UTEVA
isotope dilution
multi-collector inductively coupled plasma mass spectrometry(MC-ICP-MS)
on-line separation and preeoncentration