期刊文献+

新型废热锅炉高、低温管板试验研究 被引量:3

Research and Test of High and Low Temperature Tobesheet Used in Waste Heat Boilers
下载PDF
导出
摘要 由于管板上开有众多的不连续通孔,因而其应力分布、强度问题十分复杂,为了弄清管板的受力状态,给废热锅炉管板的强度设计提供参考资料,在没有相应规范的情况下,本文对此新型废热锅炉的管板建立了试验模型,并进行了应力测定,实测结果和有限元计算值基本上接近。 In view of the existence of many holes, the stress distribution and the strength of the tubesheets are quite complicated. In order to obtain the stress distribution in the tnbesheet so as to provide references for the design, an experiment model was established under the condition that mere is no relevant code. Then, the measurement of the stress was carried out for this model. The result of the experiment was consistence with the result from the calculation of finite element method.
机构地区 郑州工业大学
出处 《化工设备设计》 1998年第5期32-33,共2页
关键词 废热锅炉 管板 应力 锅炉 waste heat boiler,tubesheet,stress.