基于容积脉搏波的血压参数测量与标定的方法研究 被引量:4

A Calibrated Method for Blood Pressure Measurement Based on Volume Pulse Wave
下载PDF
导出
摘要 提出通过人体指端一点位置测量脉搏波传播时间,进而标定收缩压、舒张压。具体方法是通过交替点亮红光和红外光获取容积脉搏波,经放大滤波及信号处理后得到加速脉搏波,通过测量其中推进波和反射波之间的脉搏波传播时间来建立与血压的关系。根据数据回归分析建立收缩压测量方程式,根据容积脉搏波中交直流成分之间存在的线性关系及数据回归分析,建立相应的舒张压测量方程式。通过临床33例人体实验,其中18人作为训练组,15人作为对照组,并与基于传统充气袖带测量的OMRON电子血压仪测量结果作对照验证,结果表明有较好的一致性。此方法简单易行,可望作为一种无创、连续血压参数测量的标定方法。 Physiology parameters measurement based on volume pulse wave is suitable for the monitoring blood pressure continuously. This paper described that the systolic blood pressure (SBP) and diastolic blood pressure (DBP) can be calibrated by measuring the pulse propagation time, just on one point of finger tip. The volume pulse wave was acquired by lighting the red and infrared LED alternately, and after signal processing, an accelerated pulse wave was obtained. Then by measuring the pulse wave propagation time between the progressive wave and reflected wave, we can find the relationship of the time and the blood pressure, and establish the related systolic blood pressure measurement equation. At the same time, based on the relationship between alternating current and direct current components in the volume pulse waveforms and through regression analysising, the relevant diastolic blood pressure measurement equation can be established. 33 clinical experimentation cases have been worked by dividing them into two groups: training group (18 cases) and control group (15 cases), by comparing with the measuring results of the OMRON electronic sphygmomanometer. The results indicated that the two methods had good coherence. The measurement described is simple and reliable, and may be served as a new method for noninvasively and continuously measurement of blood pressure.
出处 《中国医疗器械杂志》 CAS 2010年第1期4-8,共5页 Chinese Journal of Medical Instrumentation
关键词 容积脉搏波 传播时间 收缩压 舒张压 标定 volume pulse wave, systolic blood pressure, diastolic blood pressure, Pulse Propagation time, blood pressure, calibrate
  • 相关文献

参考文献11

二级参考文献30

共引文献65

同被引文献63

  • 1彭玉华.一种改进的小波变换阈值去噪方法[J].通信学报,2004,25(8):119-123. 被引量:41
  • 2向海燕,俞梦孙.用脉搏波传导时间实现血压连续测量[J].医疗卫生装备,2006,27(2):19-21. 被引量:31
  • 3Keisuke Matsushita,Kazuo Aoki,Naoto Kakuta. Fundamental Study of Reflection Pulse Oximetry[J].{H}OPTICAL REVIEW,2003.282-287.
  • 4Sugino S,Kanaya N,Mizuuchi M. Forehead is as sensitive as finger pulse oximetry during general anesthesia[J].{H}Canadian Journal of anaesthesia-Journal canadien d anesthesie,2004.432-436.
  • 5Hauke A,Kr?mer J,Laqua D. High Performance Triple LED Driver with Digitally Controlled Analog Dimming[J].{H}BIOMEDIZINISCHE TECHNIK,2012.580-582.
  • 6Nilsson L,Goscinski T,Johansson A. Age and gender do not influence the ability to detect respiration by photoplethysmography[J].{H}JOURNAL OF CLINICAL MONITORING AND COMPUTING,2006.431-436.
  • 7Clifton D,Douglas JG,Addison PS. Measurement of Respiratory Rate from the Photoplethysmogram in Chest Clinic patients[J].{H}Journal of Clinical Monitoring and Computing,2007.55-61.
  • 8Natalini G,Rosano A,Franceschetti ME,Facchetti P,Bernardini A. Variations in arterial blood pressure and photoplethysmography during mechanical ventilation[J].{H}Anesthesia and Analgesia,2006.1182-1188.
  • 9Nitzan M,Patron A,Glik Z. Automatic noninvasive measurement of systolic blood pressure using photoplethysmography[J].{H}BioMedical Engineering OnLine,2009.28.
  • 10Shamir M,Eidelman LA,Floman Y. Pulse oximetry plethysmographic waveform during changes in blood volume[J].{H}British Journal of Anaesthesia,1999.178-181.

引证文献4

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部