期刊文献+

防止超临界锅炉不锈钢管内壁氧化物脱落堵塞爆管的措施 被引量:1

Measures of Stainless Steel Tube to Prevent the Super-critical Boiler Tube Rupture Inside of Oxides to Plug off
下载PDF
导出
摘要 文中介绍了平圩发电有限责任公司制定的3号锅炉不锈钢管氧化皮剥落堆积的检测技术措施,并对其氧化皮产生、剥落堆积的原因进行了详细分析,阐述了氧化皮剥落堆积的形式和对机组运行造成的危害,提出了可靠的防范措施,成功地消除了3号锅炉受热面管因氧化皮剥落堆积堵塞爆管的重大隐患,也给同类发电厂提供了借鉴。 This paper introduces the Pingwei Power Co. Ltd. No.3 boiler developed by oxidation of stainless steel skin peeling off the accumulated detection technology measures,and its oxide production,peeling causes accumulation of a detailed analysis to explain the accumulation of oxide skin peeling off form and the damage to the unit operation proposed a reliable preventive measures,the success of the elimination of the No.3 tube boiler heating surface oxide peeling off due to burst pipes blocked accumulation of the major risks,but also to provide a reference of similar power plants.
作者 金万里
出处 《安徽电力》 2009年第4期14-24,共11页 Anhui Electric Power
关键词 超临界锅炉 氧化皮剥落堆积 检测技术 产生机理 堆积形式和危害 防范措施 supereritical boiler oxide spalling accumulation detection technology generation mechanism accumulation forms and hazards preventive measures