摘要 针对梅县荷树园电厂国产首台自主知识产权1025 t/h循环流化床锅炉,文中对其设计上存在的风机选型大、能耗高问题,以二次风机作为典型分析,并对目前已采取的节能降耗措施进行了阐述,对提高电厂的经济效益,降低电厂的厂用电率具有积极作用。 Aiming at the first domestic produced 1 025 t/h circulating fluidized-bed combustion boiler with self-reliance intellectual property rights in Heshuyuan power plant of Mei County with respect to its design issues,i.e, the type selection of the air fan is large and the energy consumption is high,it elaborates on the measures currently adopted to achieve the energy saving and the lower consumption taking the overfire air fan for the typical analysis to play a active role in enhancing the economic benefit and reducing the station service power consumption rate of the power plant.
出处 《安徽电力》 2009年第4期47-51,共5页 Anhui Electric Power
关键词 300 MW循环流化床锅炉 风机选型大 节能降耗 300 MW circulating fluidized bed large type selection of air fan energy saving and lower consumption