期刊文献+

紫外分光光度法测定总氮空白值过高原因分析 被引量:8

Reason Analysis of High Blank Value in Determination of Total Nitrogen by UV Spectrophotometric Method
下载PDF
导出
摘要 碱性过硫酸钾消解紫外分光光度法测定总氮过程中,常常发生空白值过高而影响测定的情况,可能造成空白值过高的原因很多,主要包括纯水质量、试剂纯度、实验条件等几个方面,通过对可能造成总氮测定空白值过高的各项原因进行逐一系统分析和试验,发现造成空白值过高的原因主要为试剂过硫酸钾纯度不够,含有的总氮杂质过高所致,采用二次重结晶的方法对过硫酸钾试剂提纯后使用,同时严格地按照标准方法要求控制实验条件,即可大大降低总氮测定的空白值。 The blank value used to be high when the total nitrogen was determined by alkaline potassium persulfate digestion - UV spectrophotometric method. The reasons that could cause high blank value include water quality, reagent purity, experiment conditions and so on. All kinds of factors that could cause high blank value in measuring the total nitrogen were analyzed and tested in turn. The results indicate that impure potassium persulfate is the main reason caused high blank value. Through secondary recrystallization of potassium pcrsulfate and strict experiment conditions, the blank value will be greatly reduced.
出处 《环境科技》 2010年第1期64-66,共3页 Environmental Science and Technology
关键词 过硫酸钾 总氮 空白值 紫外光 Potassium persulfate Total nitrogen Blank value UV
  • 相关文献

参考文献3

  • 1国家环境保护局.GB11894-89水质总氯的测定碱性过硫酸钾消解紫外分光光度法[S].北京:中国标准出版社,1989.
  • 2谭爱平,钟陵,黄滨.测定总氮的影响因素探讨[J].中国环境监测,2006,22(1):58-60. 被引量:36
  • 3中华人民共和国化学工业部.GB/T641-94化学试剂过二硫酸钾(过硫酸钾)[S].北京:中国标准出版社,1994.

二级参考文献2

  • 1林华荣.碱性过硫酸钾氧化-紫外分光光度法测定水中总氮[J].环境科学与技术,1984,(4):21-24.
  • 2GB11894-89水质-总氮的测定-碱性过硫酸钾消解紫外分光光度法[S].

共引文献35

同被引文献44

引证文献8

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部