摘要 目的了解使用中洗手液污染情况及原因。方法采用现场采样和细菌检验技术,对该医院临床科室使用中洗手液染菌情况进行抽样调查。结果共抽检该医院11个临床科室123份洗手液,不合格25份,其中细菌总数超标4份,检出条件致病菌21份,超标率20.33%。在洗手液中检出铜绿假单胞菌最多,占71%,大肠埃希菌占19%,肺炎克雷伯菌和金黄色葡萄球菌各占5%。该医院不同科室使用中洗手液细菌污染超标率最高者为重症监护病房,其次是普通病区和手术室。结论该医院用于手卫生的洗手液不规范使用导致细菌污染超标严重,检出铜绿假单胞菌最多,应用感应式取液器及规范的消毒措施可提高合格率。 Objective To investigate bacterial contamination of hand sanitizer in use and the causes. Methods A sample survey on bacterial contamination of hand sanitizer in use in clinical departments of the hospital was carried out by on - site sampling and bacteriological examination techniques. Results 123 samples of hand sanitizer in 11 clinical departments of the hospital were taken. Of them, 25 were unqualified, including 4 exceeded the allowable limit of bacteria, and 21 were found to have opportunistic pathogens, with rate of exceeding allowable limit being 20.33%. Among the detected bacteria, Pseudomonas aeruginosa was the main bacteria, accounting for 71%, Escherichia coli accounted for 19%, Klebsiella pneumoaiae and Staphylococcus aureus each accounted for 5%. Among the departments in which bacterial con- tamination exceeded allowable limit, the highest rate of contamination was the intensive care unit, followed by the general wards and operating rooms. Conclusions Bacteria contamination of the hand sanitizer in this hospital seriously exceeded the allowable limit, and Pseudomonas aeruginosa was the most frequently detected bacteria. Contamination in key depart- ments was most serious.
作者 陈玉芹 王娟
出处 《中国消毒学杂志》 CAS 2010年第1期57-58,共2页 Chinese Journal of Disinfection
关键词 洗手液 细菌污染 调查 hand sanitizer bacterial contamination survey
  • 相关文献

参考文献2

二级参考文献10

共引文献68

同被引文献14

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部