摘要
以实际焦化废水经A2O工艺处理后的出水为研究对象,考察了Fenton试剂氧化法深度处理焦化废水的效果和影响因素。结果表明,Fenton试剂氧化法对焦化废水具有良好的深度处理效果,在进水COD为100~340mg/L、色度为480~940倍的条件下,出水COD和色度等指标均可达到《城市污水再生利用工业用水水质》(GB/T19923—2005)的要求。在试验条件下,最佳的反应参数:初始pH值为2.5,反应温度为40~50℃,Fe2+投加量为0.4mmol/L,反应时间为2~3h,H2O2投加量为4~8mmol/L。
Taking the actual coking wastewater treated by A20 process as research object, the efficiency and influencing factors in advanced treatment of the coking wastewater by Fenton reagent oxidation process was investigated. The results show that the Fenton reagent oxidation process has high treatment efficiency of coking wastewater. When the influent COD is 100 to 340 mg/L, and color is 480 to 940 times, the effluent COD and color can reach the requirements of the Reuse of Urban Recycling Water -- Water Quality Standard for Industrial Uses (GB/T 19923 -2005 ). The optimal operating conditions are as follows : initial pH is 2.5, reaction temperature is 40 to 50℃, Fe^2 + dosage is 0. 4 mmol/L, reaction time is 2 to 3 h, and H2O2 dosage is 4 to 8 mmol/L.
出处
《中国给水排水》
CAS
CSCD
北大核心
2010年第3期93-95,共3页
China Water & Wastewater
基金
国家火炬计划项目(2009GH060062)
关键词
焦化废水
FENTON试剂
氧化
深度处理
影响因素
coking wastewater
Fenton reagent
oxidation
advanced treatment
influencing factors