要完成中压电机起动网压降的正确计算,就必须正视其它负载的存在,并从伏安特性上区分它们。其它负载给计算带来麻烦。介绍了大电机恒流起动网压降计算软件(CV1)具有适应性强和便于使用的特点。
To calculate the net voltage drop caused by MV motor's starting accurately, the other loads linked with the net, including their type distribution, must be considered. The task of calculation is therefore complicated. A calculation software (CV 1 ) is introduced, which is comprehensive and convenient.