期刊文献+

Development of an optical probe to measure the flattened area of ocular cornea 被引量:2

Development of an optical probe to measure the flattened area of ocular cornea
原文传递
导出
摘要 The optical probe in tonometers is a key component in measuring the flattened diameter or area of the ocular cornea. A new kind of optical probe for the direct measurement of the flattened area of the ocular cornea is presented. The optical probe uses the cone prism with a modulating flake of light intensity as its measuring body. The test results on simulated eyeballs with different radii of curvature of the ocular cornea show that there is a linear relation between the flattened area of the ocular cornea and the normalized current. The optical probe, which is more compact compared with existing optical probes and easily configured with its coaxiality of optical parts, may be an excellent probe for constructing a low-cost, miniaturized applanation tonometer. The optical probe in tonometers is a key component in measuring the flattened diameter or area of the ocular cornea. A new kind of optical probe for the direct measurement of the flattened area of the ocular cornea is presented. The optical probe uses the cone prism with a modulating flake of light intensity as its measuring body. The test results on simulated eyeballs with different radii of curvature of the ocular cornea show that there is a linear relation between the flattened area of the ocular cornea and the normalized current. The optical probe, which is more compact compared with existing optical probes and easily configured with its coaxiality of optical parts, may be an excellent probe for constructing a low-cost, miniaturized applanation tonometer.
出处 《Chinese Optics Letters》 SCIE EI CAS CSCD 2010年第1期103-106,共4页 中国光学快报(英文版)
基金 supported by the Natural Science Foundation of Anhui Provincial Education Department(Nos. KJ2008B262,KJ2008A146,and 2007jq1092)
关键词 OPTICS PHYSICS Optics Physics
  • 相关文献

参考文献11

  • 1A. W. Siu, M. C. P. Leung, C. H. To, F. K. W. Siu, J. Z. Ji, and K. F. So, Exp. Eye Res. 75, 401 (2002).
  • 2K. C. Katuri, S. Asrani, and M. K. Ramasubramanian, IEEE Sens. J. 8, 12 (2008).
  • 3G. K. Krieglstein and W. K. Waller, Graefes Arch. Clin. Exp. Ophthal. 194, 11 (1975).
  • 4J. H. Fisher, P. G. Watson, and G. Spaeth, Eye 2, 238 (1988).
  • 5C. Kniestedt and H. E. Kanngiesser, Ophthalmologe 8, 713 (2006).
  • 6E. Perkins, Br. J. Opthalmol. 49, 591 (1965).
  • 7M. Kong, Z. Gao, L. Chen, and X. Li, Chin. Opt. Lett. 6, 377 (2008).
  • 8J. Draeger, "Applanation tonometer" U.S. Patent 005203331A (Apr. 30, 1993).
  • 9S. Asrani, R. Zeimer, J. Wilensky, D. Gieser, S. Vitale, and K. Lindenmuth, J. Glaucoma 9, 134 (2000).
  • 10J. Lasseck, T. Jehle, N. Feltgen, and W. A. Lagreze, Graefes Arch. Clin. Exp. Ophthalmol. 246, 1463 (2008).