期刊文献+

Phase Contrast Micro-Computed Tomography of Biological Sample at SSRF 被引量:2

Phase Contrast Micro-Computed Tomography of Biological Sample at SSRF
原文传递
导出
摘要 In line X-ray phase contrast micro-computed tomography (IL-XPCT), which can be implemented at third generation synchrotron radiation sources or by using a micro-focus X-ray tube, is a powerful technique for non-destructive, high-resolution investigations of a broad variety of materials. At the Shanghai Synchrotron Radiation Facility (SSRF), the X-ray Imaging and Biomedical Applications Beamline was built and started regular user operation in May 2009. Both qualitative (without phase retrieval) and quantitative (with phase retrieval) three-dimensional IL-XPCT experimental techniques have been established at the beamline IL-XPCT experiments of a test sample (plastic pipes) used to evaluate the technique, and of a biological sample (locust) at the beamline are reported. Two series of images, qualitative and quantitative, including tomographic slices and three-dimensional rendering images were obtained. In qualitative images, there is a strong edge-enhancement which leads to very clear sample contours, while in quantitative images, the edge-enhancement fades but quantitative measurement of sample's phase information could be achieved. The experiments demonstrate that the combination of qualitative and quantitative images is useful for biological sample studies. In line X-ray phase contrast micro-computed tomography (IL-XPCT), which can be implemented at third generation synchrotron radiation sources or by using a micro-focus X-ray tube, is a powerful technique for non-destructive, high-resolution investigations of a broad variety of materials. At the Shanghai Synchrotron Radiation Facility (SSRF), the X-ray Imaging and Biomedical Applications Beamline was built and started regular user operation in May 2009. Both qualitative (without phase retrieval) and quantitative (with phase retrieval) three-dimensional IL-XPCT experimental techniques have been established at the beamline IL-XPCT experiments of a test sample (plastic pipes) used to evaluate the technique, and of a biological sample (locust) at the beamline are reported. Two series of images, qualitative and quantitative, including tomographic slices and three-dimensional rendering images were obtained. In qualitative images, there is a strong edge-enhancement which leads to very clear sample contours, while in quantitative images, the edge-enhancement fades but quantitative measurement of sample's phase information could be achieved. The experiments demonstrate that the combination of qualitative and quantitative images is useful for biological sample studies.
出处 《Tsinghua Science and Technology》 SCIE EI CAS 2010年第1期102-107,共6页 清华大学学报(自然科学版(英文版)
基金 Supported by the Major Research Plan of the National Natural Science Foundation of China (No.2010CB834301) the National Natural Science Foundation of China (Nos.10805071 and 10705020) the Chinese Academy of Sciences Key Project of International Co-operation (No.GJHZ09058) the Shanghai Key Project of Basic Research (No.08JC1411900) supported by ICTP TRIL Programme
关键词 X-RAY phase contrast tomography phase retrieval synchrotron radiation X-ray phase contrast tomography phase retrieval synchrotron radiation
  • 相关文献

参考文献14

  • 1Hounsfield G.Computeried transversal axial scanning (tomography):Part I.description of system.Brit.J.Radiol.,1973,46:1016-1022.
  • 2Fitzgerald R.Phase-sensitive X-ray imaging.Phys.Today,2000,53(7):23-26.
  • 3Xiao T Q,Bergamaschi A,Dreossi D,et al.Effect of spatial coherence on application of in-line phase contrast imaging to synchrotron radiation mammography.Nucl.Instrum.Meth.A,2004,548(1-2):155-162.
  • 4Wu X Z,Liu H,Yah A.Phase-contrast X-ray tomography:Contrast mechanism and roles of phase retrieval.Eur.J.RadioL,2008,68(3):S8-S12.
  • 5Nugent K A,Gureyev T E,Cookson D F,et al.Quantitative phase imaging using hard X rays.Phys.Rev.Lett.,1996,77(14):2961-2964.
  • 6Paganin D,Nugent K A.Noninterferometric phase imaging with partially coherent light.Phys.Rev.Lett.,1998,80(12):2586-2589.
  • 7Guigay J P.Fourier-transform analysis of fresnel diffraction patterns and in-line holograms.Optik.,1977,49(1):121-125.
  • 8Cloeteus P,Ludwig W,van Dyck D,et al.Quantitative phase tomography by holographic reconstruction.In:Proceedings of SPIE.Denver,CO,USA,1999:279-290.
  • 9Gttreyev T E,Pogany A,Paganin D M,et al.Linear algorithms for phase retrieval in the Fresnel region.Opt.Commun.,2004,231(1-6):53-70.
  • 10Gureyev T E,Davis T J,Pogany A,et al.Optical phase retrieval by use of first Born-and Rytov-type approximations.Appl.Opt.,2004,43(12):2418-2430.

同被引文献15

引证文献2

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部