摘要 A control system used in high performance liquid chromatograph(HPLC) was described.The control system adopting low pressure gradient elution was tested with different initial and end volume fractions,and four types of gradient elution curves.The experimental results verified the theoretical analyses of the applied method.This self-designed control system can achieve approving accuracy,repeatability and low cost,which has a bright outlook for domestic applications. A control system used in high performance liquid chromatograph (HPLC) was described. The control system adopting low pressure gradient elution was tested with different initial and end volume fractions, and four types of gradient elution curves. The experimental results verified the theoretical analyses of the applied method. This self-designed control system can achieve approving accuracy, repeatability and low cost, which has a bright outlook for domestic applications.
出处 《Journal of Shanghai Jiaotong university(Science)》 EI 2010年第1期54-57,共4页 上海交通大学学报(英文版)
基金 the National High Technology Research and Development Program (863) of China(No. 2009AA04Z326) the National Natural Science Foundation of China (Nos. 60671059, 60871091 and60588101) the National Basic Research Program (973) of China (Nos. 2005CB724302 and 2005CB724303) the 111 Project from the Ministry of Education of China(No. B08020)
关键词 low pressure GRADIENT high performance liquid chromatograph (HPLC) MIXER 低压控制系统 混合器 谱梯度 高效液相色谱法 体色 性能 梯度洗脱 HPLC
  • 相关文献

参考文献6

  • 1BERRIDGE S A. Techniques for the automated optimization of HPLC separations [M]. Chichester: John Wiley and Sons, 1985.
  • 2BIDLINGMEYER B A. Practical HPLC methodology and applications [M]. New York : John Wiley and Sons, 1992.
  • 3DEYL Z. Separation methods [M]. Amsterdam: Elsevier, 1984.
  • 4HSU A J, LAUB R J, MADDEN S J. Solute retention in column liquid chromatography. I. Binary non- electrolyte mobile-phase additives at high dilution with silica sorbent [J]. Journal of Liquid Chromatography and Related Technologies, 1984, 7(3): 599-614.
  • 5HSU A J, LAUB R J, MADDEN S J. Solute retention in column liquid chromatography. II. Optimization of mobile-phase compositions [J]. Journal of Liquid Chromatography and Related Technologies, 1984, 7(3): 615- 637.
  • 6WEYLAND J W, BRUINS C H P, DOOMBOS D A. Use of three-dimensional minimum a-plots for optimization of mobile phase composition for RP-HPLC separation of sulphonamides [J]. Journal of Chromatographic Science, 1984, 22: 31-39.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部