摘要
传统的状态估计把量测方程作为约束条件,以量测残差的加权平方和或加权绝对值之和最小等为目标函数进行估计,因而不能直接辨识出拓扑错误。为了同时辨识拓扑错误和不良数据,文中把转移潮流方程增广为状态估计的约束条件,在目标函数中同时计及转移潮流的残差和量测残差,对已有的加权最小绝对值状态估计进行了改进,提出了可以同时辨识支路拓扑错误和不良数据的状态估计模型。文中给出了某省实际电网的计算实例。
The objective functions of traditional state estimation are to get the weighted least squares of the residual sum or the weighted least absolute value of the residual sum and so on,constrained by measurement function,thus could not identify topology error directly.In order to identify topology error and bad data at the same time,this paper extends the transfer power flow function as constraints,while taking account of the residual of transfer power flow as well as the measurement residual in the objective function.By improving the existing weighted least absolute value state estimation,a new state estimation model is proposed for identifying the topology error and bad data simultaneously.Its performances are highlighted via simulations performed on a real provincial power network.
出处
《电力系统自动化》
EI
CSCD
北大核心
2010年第2期39-42,63,共5页
Automation of Electric Power Systems
关键词
状态估计
加权最小二乘估计
加权最小绝对值估计
转移潮流
拓扑错误辨识
不良数据辨识
state estimation
weighted least squares estimation
weighted least absolute value estimation
transfer power flow
topology error identification
bad data identification