摘要
文章对下福水电站灯泡贯流式机组励磁系统故障进行分析,介绍了处理办法,尤其是集电环的现场处理方法,并加以总结。
The paper studies the excitation system fault of bulb tubular unit at Xiafu Hydropower Station, and proposes the method of treatment, especially the site treatment method by collector ring.
出处
《红水河》
2010年第1期70-71,共2页
Hongshui River
关键词
贯流式机组
励磁系统
集电环
故障
处理
下福水电站
tubular unit
excitation system
collector ring
fault
treatment
Xiafu Hydropower Station