期刊文献+

高温除湿干燥的节能分析 被引量:6

Energy Consumption Analysis for High-Temperature and Dehumidification Drying
下载PDF
导出
摘要 对杨木进行高温除湿干燥,并与常规干燥进行干燥能耗和木材质量的对比。结果表明,高温除湿干燥各阶段节能效果有较大差异,前期节能效果最好,平均能量回收率为30.5%;在同样的干燥基准下,两者的干燥周期和干燥质量基本一致,高温除湿干燥比常规干燥节能34.1%。未来的发展方向是高温除湿干燥与常规干燥联合进行。 Populus deltoides lumber were dried using high temperature dehumidification and conventional methods under the same schedule. Energy consumption and drying quality during the two drying methods were monitored and compared. Results showed that the energy consumption was different during various drying stages. It was found that the most effective way to save energy was in the initial period and it could save up to 30.5%, The high-temperature dehumidification drying consumed 34.1% less energy than the conventional drying without compromising the drying quality. It was expected that high-temperature dehumidification would increase its popularity along with the conventional drying in the future.
出处 《木材工业》 北大核心 2010年第2期21-23,共3页 China Wood Industry
基金 "十一五"国家科技支撑计划项目(2006BAD18B0802)
关键词 高温干燥 除湿干燥 节能 杨木 high temperature drying dehumidification drying energy saving Populus Deltoides
  • 相关文献

参考文献7

二级参考文献11

  • 1苗天杰.在新形势下,进一步搞好节能降耗工作[J].节能技术,1993,11(1):2-4. 被引量:1
  • 2王喜平,张璧光,赵忠信.高温热泵除湿干燥技术的初步研究[J].木材工业,1994,8(4):11-13. 被引量:14
  • 3张璧光,赵忠信,霍光青.除湿干燥的节能分析[J].林产工业,1995,22(6):35-38. 被引量:24
  • 4朱政贤,木材干燥,1992年
  • 5张璧光,林产工业,1990年,2期,18页
  • 6宋沐,林业机械,1988年,1期,46页
  • 7宋闯,木材干燥.理论、实践和经济,1985年
  • 8Paul B. Heat pump dehumidifier drying technology-status,potential and prospects [C]. 7th International Energy Agency Conference, Beijing, 2002,219-230.
  • 9Xie Y, Zhang B, Chang J, et al. Development and experiment of dehumidification wood dryer with multi-function [J].2001,3 (2): 158-161.
  • 10张钟光.成材窑干热平衡和能源利用分析[J]南京林业大学学报(自然科学版),1982(01).