期刊文献+

超临界600MW机组给水控制策略 被引量:8

THE CONTROL STRATEGY OF FEED WATER FOR SUPERCRITICAL 600 MW UNIT
下载PDF
导出
摘要 超临界600 MW机组的给水控制特性是一个复杂多变且多变量对象。针对直流炉给水调节既与负荷控制相关又与蒸汽温度控制相关的特点,给水控制系统采用控制燃料与给水比值的方式,进而通过二者的解耦回路来保证合适的燃水比,燃水比的稳定又确保了过热蒸汽温度和锅炉压力的基本稳定。 The control characters of feed water for supercritical 600 MW unit is a complex and frequently varying object with multiple variables. The features of feed water regulation are related to both load control and temperature control, the feed water control system adopts a mode of cotrolling the ratio between fuel and feed water,and then through decoupling circuit of fuel and feed water to ensure an approprate fuel- water ratio. The stability of fuel -water ratio again ensures the basic stability of superheated steam temperature and the boiler pressure.
出处 《热力发电》 CAS 北大核心 2010年第2期78-81,84,共5页 Thermal Power Generation
关键词 火电厂 超临界 600 MW机组 给水 控制 微过热蒸汽焓值 燃水比 thermal power plant supercritical 600 MW unit feed water control enthalpy value of microsuperheated steam fuel - water ratio