期刊文献+

长廊型高层建筑火灾烟气控制模式的效果比较 被引量:23

Effect comparison of smoke control model in high-rise building with corridor
下载PDF
导出
摘要 为研究走廊中常见烟气控制模式的效果,采用数值模拟与全尺寸长廊实验相结合的方法,对采用挡烟垂壁、机械排烟和空气幕等多种组合的防排烟模式的防排烟效果进行分析。比较各种模式下烟气的温度分布、质量分数分布以及烟气沉降时间,设计5种排烟模式。结果表明:防烟空气幕效果明显。采用前室部分加压并在前室门口设置防烟空气幕,同时开启两个排烟口的排烟模式具有最佳的烟气控制效果,其排烟效率达到74.52%。 The numerical simulation combined with the full size experiment has been used to analyze effect of common ,smoke control modes. The smoke-proof pendant wall, mechanical smoke exhaust and air curtain were used in these 5 modes. The smoke temperature distribution, mass fraction distribution, and smoke down time between these modes were compared. The results shown that smoke preventing air curtain and pressurization in atria, with two exhaust ports in aisle has the best smoke control effect, which has smoke removal efficiency about 74.52%.
出处 《消防科学与技术》 CAS 北大核心 2010年第1期33-36,共4页 Fire Science and Technology
基金 江苏省自然科学基金(BK2008369)
关键词 高层建筑 烟气控制 数值模拟 空气幕 挡烟垂壁 high-rise building smoke control numerical simulation air curtain smoke-proof pendant wall
  • 相关文献

参考文献7

二级参考文献33

共引文献157

同被引文献139

引证文献23

二级引证文献77

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部