期刊文献+

对比剂团注跟踪技术在下肢动脉造影中的应用 被引量:8

Application of Bolus Chasing Technology in Limb Artery Angiography
下载PDF
导出
摘要 目的:探讨对比剂团注跟踪造影技术(Bolus Chasing)在下肢动脉造影中的临床应用价值及其质量控制。方法:采用对比剂团注跟踪技术对33例患者行下肢动脉造影,并与传统DSA分段造影法(12例)进行对比,分别比较二者的患者X线吸收剂量、对比剂用量、造影完成时间,并对团注跟踪造影图像质量进行分级评价。结果:对比剂团注跟踪技术和传统DSA分段造影法完成单侧下肢动脉造影患者X线吸收剂量分别为(11.00±1.37)mGy和(22.33±2.23)mGy,对比剂用量分别为(19.27±1.92)ml和(28.50±2.28)ml,造影完成时间分别为(4.38±0.49)min和(12.37±0.84)min,差异具有显著性意义(P<0.05)。结论:采用对比剂团注跟踪技术进行下肢动脉造影较传统分段造影技术具有使用对比剂少、检查时间短、图像直观等优点,且能一次性准确显示全下肢血管的解剖情况,值得临床进一步推广应用。 Objective:To study the value of bolus chasing technology in limb artery angiography and its quality control. Methods:33 cases underwent lower limb artery angiography by using bolus chasing technology,and 12 eases by using traditional DSA segmentation method. The radiation dose, the dosage of contrast agents, completion time and image quality were compared between the two groups. Results.. The radiation dose were (11.00± 1.37)mGy (bolus chasing group) and (22.33± 2.23)mGy (traditional DSA segmentation method), respectively. The dosage of contrast agents were (19.27±1.92)ml and (28.50±2.28)ml,respectively. And the completion time were (4.38±0.49)min and (12.37±0.84)rain. Conclasion:Bolus chasing technology is a good method in limb artery angiography with a low dose of radiation,a short time of examination and good quality of imaging.
出处 《放射学实践》 北大核心 2010年第2期208-210,共3页 Radiologic Practice
关键词 血管造影术 数字减影 下肢 评价研究 Angiography,digital subtraction Lower extremity Evaluation studies
  • 相关文献

参考文献6

  • 1蒋雄京,高润霖.外周动脉病经皮介入治疗现状与进展[J].中华心血管病杂志,2007,35(8):781-784. 被引量:4
  • 2余建民.数字减影血管造影技术[M].北京:人民军医出版社,1999.283-284.
  • 3李麟孙,贺能树,邹英华.介入放射学基础与方法[M].北京:人民卫生出版社,2005.338-339.
  • 4中华人民共和国医政司.放射科管理和技术规程(试行本)[M].北京:北京医科大学、中国协和医科大学联合出版社,1991.50-52.
  • 5Ashleigh R J, Hufton AP, Razzsq R, et al. A Comparision of Bolus Chasing and Static Digital Substraction Arteriography in Peripheral Vascular Disease[J]. Br J Radial,2000,73(872) :819.
  • 6王沆,郭平凡.造影剂肾病[J].医学综述,2007,13(8):594-596. 被引量:18

二级参考文献54

  • 1Wang A,Holcslaw T,Bashore TM,et al.Exacerbation of radiocontrastnephrotoxicity by endothellin receptor antagonism[J].Kidney Int,2000,57(4):1675-1680.
  • 2Porter GA.Contrast medium-associated nephropathy:Recognitionand management[J].Invest Radiol,1993,28(S4):S11-S18.
  • 3Fishbane S,Durham JH,Marzo K,et al.N-acetylcysteine in theprevention of radiocontrast-induced nephropathy[J].J Am Soc Nephrol,2004,15(2):251-260.
  • 4Prasad PV,Priatna A,Spokes K,et al.Changes in intrarenal oxygenation as evaluated by BOLD MRI in a rat kidney model for radiocontrast ephropathy[J].J Maqn Reson Imaging,2001,13(5):744-747.
  • 5Murphy SW,Barrett BJ,Parfrey PS.Contrast nephropathy[J].J Am Soc Nephrol,2000,11 (1):177-182.
  • 6Waybill MM,Waybill PN.Contrast media-induced nephrotoxicity:identification of patients at risk and algorithms for prevention[J].J Vasc Interv Radiol,2001,12(1):3-9.
  • 7Asif A,Preston RA,Roth D.Radiocontrast-induced nephropathy[J].Am J Ther,2003,10(2):137-147.
  • 8Hizoh I,Haller C.Radiocontrast-induced renal tubular cell apoptosis[J].Invest Radiol,2002,37(8):428-534.
  • 9Stouffer GA,Aqrawal M.Contrast Induced Nephropathy after Angiography[J].Am J Med Sci,2002,323(5):252-238.
  • 10Soma VR,Cavusoglu E,Vidhun R,et al.Contrast-Associated Nephropathy[J].Heart Dis,2002,4(6):372-379.

共引文献28

同被引文献38

引证文献8

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史